background image

Before

 

You

 

Begin

 

Page

 

1

 

of 14 

  Before

 

You

 

Begin 

1

.

What

 

Is

 

Included

 

 Artnet DMX controller 

 

IEC

 

power

 

cord 

 Warranty card 

User

 

Manual

 

 

Unpacking

Carefully unpack

 

the

 

fixtrue and

 

check that

 

all

 

the

 

parts

 

are

 

in

 

the

 

package,

 

and

 

are

 

in

 

good

 

condition

.

 

Claims 

Upon

 

receipt

if

 

the

 

container

 

or

 

the

 

contents 

(

the

 

product and

 

included

 

accessories

appear

 

damaged

 

from

 

shipping

or

 

show

 

signs

 

of

 

mishandling

notify  the

 

carrier

 

immediately

Failure

 

to

 

do

 

so

 

in

 

a

 

timely manner

 

may invalidate

 

your

 

claim

 

with

 

the

 

carrier

In

 

addition

keep

 

the

 

container

 

and

 

all

 

the

 

packing

 

material

 

for

 

inspection

.

 

For

 

other

 

issues

 

such

 

as

 

missing

 

components

 

or

 

parts

damage

 

not

 

related

 

to

 

shipping

or

 

concealed

 

damage

file

 

a

 

claim

 

with

 

us within

 

7

 

days

 

of

 

receiving

 

the

 

merchandise

.

 

For

 

information

 

on

 

contacting

 

us

see

 

Contact

 

Us at

 

the

 

end

 

of

 

this Manual

Symbols 

Symbols 

Meaning 

 

Critical

 

installation

configuration

or

 

operation

 

information

Failure

 

to

 

comply

 

with

 

this

 

information

 

may

 

cause

 

the

 

product

 

not

 

to

 

work

damage

 

third

-

party equipment

or

 

cause

 

harm

 

to

 

the

 

operator

.

 

 

Important

 

installation

 

or

 

configuration

 

information

Failure

 

to

 

comply

 

with

 

this 

information

 

may

 

keep

 

the

 

product

 

from

 

working

.

 

 

Useful

 

information

.

 

Summary of Contents for 8 Port Artnet Node

Page 1: ...GiANT 8 Port Artnet Node...

Page 2: ...onnection 6 Signal Connection Diagram 6 Installation Guidelines 6 Configuration And Operation 4 Control Panel 7 7 Menu Map 8 Using The Menu 8 Configuring Net Address 8 Configuring Subnet Address 8 Con...

Page 3: ...e carrier In addition keep the container and all the packing material for inspection For other issues such as missing components or parts damage not related to shipping or concealed damage file a clai...

Page 4: ...are no flammable materials close to the product when it is operating This product is not intended for permanent installation Never connect the product to a dimmer or a rheostat Always install the pro...

Page 5: ...Neutrik ether CON ports Neutrik ether CON ports are through ports that allow daisy chaining of the fixture units The fixture provides a reliable highly customizable network infrastructure for complex...

Page 6: ...Introduction Product Dimensions 1 7 in 44 4 mm 17 4 in 443 mm 6 6 in 167 9 mm 15 3 in 390 mm 19 in 483 mm 4 7 in 120 mm 0 9 in 23 5 mm Menu LINK DATA DMX1 DMX2 Page 4 of 14...

Page 7: ...circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch Fuse Replacement 1 Disconnect the product from power 2 Wedge the tip of a flat head screwdriver into the slot of the fus...

Page 8: ...s used as part of a control system for operating various lighting and multi media products The physical and digital construction of the control network is determined by the location and signal needs o...

Page 9: ...sed as anArt Net hub in which casethe Art Net universes must be assigned to the DMX Out ports and the Net Subnet and IP address settings must be configured can be used as both a DMX splitter and an Ar...

Page 10: ...xture device ID The menu is used by pressing the 4 control buttons as described in the next sections Configuring Net Using the menu Address The Net is the address of the network on which the fixture i...

Page 11: ...configured to accept signal from either one of the DMX I n ports or from the Art Net source If the DMX port is not being used it should be turned off The menu structure presents each DMXOut port as a...

Page 12: ...s on the display b Press RIGHT RIGHT RIGHT RIGHT RIGHT RIGHT RIGHT The phrase in the lower right hand corner of the display flashes c Press UP or DOWN until Without Input shows in the lower right hand...

Page 13: ...ng the following a Press MENU repeatedly until IP Address 1 shows in the display b Press The left most set of 3 digits on the display flashes c Press UP or DOWN until those numbers show 255 d Press Th...

Page 14: ...e display h Press 8 stops flashing Art Net And DMX Sources Art Net and DMX sources configuration uses the fixture as both a DMX splitter and Art Net adapter Configure this operating mode by combining...

Page 15: ...m temperature 3 Use a vacuum or dry compressed air and a soft brush to removedust collected on the external vents 4 Clean all external surfaces with a mild solution of non ammonia cleaner or isopropyl...

Page 16: ...rnal 100 to 240 VAC 50 60 Hz Auto ranging Parameter 120 V 60 Hz 208 V 60 Hz 230 V 50 Hz Consumption 10 W 10 W 10 W Operating Current 0 25 A 0 14 A 0 13 A Power Connection Power Input Edison Plug to IE...

Reviews: