Configuration

 

And

 

Operation

 

5

.

  Configure

 

the  DMX  ports  that

 

will

 

receive  Art

-

Net

?

  signals

 

by  doing

 

the

 

following

 

for

 

DMX Out

 

ports

 

1

 

and

 

2

:

 

a

)

  Press

 <

MENU

>

 repeatedly until

 <

DMX

 

Output

 

Port

 #

X

>

 shows

 

on

 

the

 

display

.

 

b

)

  Press

 

The

 

phrase in

 

the

 

lower

 

right

-

hand

 

corner

 

of

 

the

 

display flashes

.

 

c

)

  Press

 <

UP

>

 or 

<

DOWN

>

 until

 <

ArtNet

 

Input

>

 shows

 

in

 

the

 

lower

 

right

-

hand

 

corner

.

 

d

)

  Press

 

. <

ArtNet

 

Input

>

 stops

 

flashing

.

 

6

.

  Configure

 

Art

-

Net

 

universe for  the DMX ports that

 

will

 

receive Art

-

Net  by doing

 

the

 

following

:

 

a

)

 

<

MENU

>

 repeatedly until

 <

Universe

 #

1

>

 shows

 

in

 

the

 

display

b

)

  Press

 

The

 

number

 

in

 

the

 

lower

 

right

-

hand

 

corner

 

of

 

the

 

display flashes

.

 

c

)

  Press

 <

UP

>

 or 

<

DOWN

>

 until

 

4

 shows on

 

the

 

display

d

)

  Press

 

4

 stops

 

flashing

.

 

e

)

 

<

MENU

>

 repeatedly until

 <

Universe

 #

2

>

 shows

 

in

 

the

 

display

f

)

  Press

 

The

 

number

 

in

 

the

 

lower

 

right

-

hand

 

corner

 

of

 

the

 

display flashes

.

 

g

)

  Press

 <

UP

>

 or 

<

DOWN

>

 until

 

8

 shows

 

on

 

the

 

display

.

 

h

)

  Press

 

8

 stops

 

flashing

.

 

Art

-

Net  And

 

DMX

 

Sources 

Art

-

Net

 

and

 

DMX

 

sources

 

configuration

 

uses   the fixture   as  both

 

a

 

DMX  splitter  and

 

 

Art

-

Net   adapter

Configure

 

this  operating

 

mode

 

by

 

combining

 

the

 

configurations  for

 

the

 

DMX source  and

 

the

 

 Art

-

Net   source

which

 

are

 

described

 

in

 

detail

 

in

 

DMX

 

Source and

 

 

Art

-

Net  Source

 

Keep

 

the

 

following

 

in

 

mind

 

when

 

configuring

 

the  fixture

 

  for

 

use

 

as   a  combination  optical 

DMX splitter and Art

-

Net  adapter

Disable

 

any unused

 

DMX

 

Out

 

ports

.

 

DMX Out

 

ports

 

can

 

output

 

only DMX

 

or

 

Art

-

Net

not both

.

 

Indicators 

The

 

three

 

LED

 

indicator lights

 

on

 

the

 

front

 

of

 

the fixture

  , 

next

 

to

 

the

 

menu

 

display

indicate

 

when there is power

DMX,

 

or Art

-

Net

The

 

table below

 

shows

 

the behavior

 

of the lights

 

and

 

what

 

it

 

means

.

 

Indicator 

Behavior 

Meaning 

POWER

 

Solid

 

red 

Power

 

is

 

getting to

 

the fixture

 

 

Off 

Power

 

is

 

not getting

 

to

 

the fixture

 

SIGNAL

 

Blinks

 

red 

Art

-

Net

signal

 

is

 

getting

 

to

 

the

 

fixture  

Off 

Art

-

Net

signal

 

is

 

not

 

getting

 

to

 

the

 

fixture  

DMX 

Blinks

 

red 

DMX signal

 

is

 

getting

 

to

 

the fixture

Off 

DMX signal

 

is

 

not getting

 

to

 

the

 

fixture  

Summary of Contents for 8 Port Artnet Node

Page 1: ...GiANT 8 Port Artnet Node...

Page 2: ...onnection 6 Signal Connection Diagram 6 Installation Guidelines 6 Configuration And Operation 4 Control Panel 7 7 Menu Map 8 Using The Menu 8 Configuring Net Address 8 Configuring Subnet Address 8 Con...

Page 3: ...e carrier In addition keep the container and all the packing material for inspection For other issues such as missing components or parts damage not related to shipping or concealed damage file a clai...

Page 4: ...are no flammable materials close to the product when it is operating This product is not intended for permanent installation Never connect the product to a dimmer or a rheostat Always install the pro...

Page 5: ...Neutrik ether CON ports Neutrik ether CON ports are through ports that allow daisy chaining of the fixture units The fixture provides a reliable highly customizable network infrastructure for complex...

Page 6: ...Introduction Product Dimensions 1 7 in 44 4 mm 17 4 in 443 mm 6 6 in 167 9 mm 15 3 in 390 mm 19 in 483 mm 4 7 in 120 mm 0 9 in 23 5 mm Menu LINK DATA DMX1 DMX2 Page 4 of 14...

Page 7: ...circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch Fuse Replacement 1 Disconnect the product from power 2 Wedge the tip of a flat head screwdriver into the slot of the fus...

Page 8: ...s used as part of a control system for operating various lighting and multi media products The physical and digital construction of the control network is determined by the location and signal needs o...

Page 9: ...sed as anArt Net hub in which casethe Art Net universes must be assigned to the DMX Out ports and the Net Subnet and IP address settings must be configured can be used as both a DMX splitter and an Ar...

Page 10: ...xture device ID The menu is used by pressing the 4 control buttons as described in the next sections Configuring Net Using the menu Address The Net is the address of the network on which the fixture i...

Page 11: ...configured to accept signal from either one of the DMX I n ports or from the Art Net source If the DMX port is not being used it should be turned off The menu structure presents each DMXOut port as a...

Page 12: ...s on the display b Press RIGHT RIGHT RIGHT RIGHT RIGHT RIGHT RIGHT The phrase in the lower right hand corner of the display flashes c Press UP or DOWN until Without Input shows in the lower right hand...

Page 13: ...ng the following a Press MENU repeatedly until IP Address 1 shows in the display b Press The left most set of 3 digits on the display flashes c Press UP or DOWN until those numbers show 255 d Press Th...

Page 14: ...e display h Press 8 stops flashing Art Net And DMX Sources Art Net and DMX sources configuration uses the fixture as both a DMX splitter and Art Net adapter Configure this operating mode by combining...

Page 15: ...m temperature 3 Use a vacuum or dry compressed air and a soft brush to removedust collected on the external vents 4 Clean all external surfaces with a mild solution of non ammonia cleaner or isopropyl...

Page 16: ...rnal 100 to 240 VAC 50 60 Hz Auto ranging Parameter 120 V 60 Hz 208 V 60 Hz 230 V 50 Hz Consumption 10 W 10 W 10 W Operating Current 0 25 A 0 14 A 0 13 A Power Connection Power Input Edison Plug to IE...

Reviews: