FOR POLYPROPYLENE PIPE FROM DURAVENT
(Polypro single wall gas vent system):
PolyPro
®
InnoFlue
®
Make sure that all horizontal runs have a minimum rise of 1/4
inch per foot (21 mm/m) of run. Follow instruction of the vent
pipe manufacturer for proper vent support.
Pipe Assembly
DANGER
WARNING
CAUTION
AVERTISSEMENT
ATTENTION
ALWAYS
read and abide by all safety messages printed on
the primer, cleaner, and cement containers. Primer, cleaner,
and cements are extremely flammable.
DO NOT
store these
products near heat, sparks, or flames. They are harmful or
fatal, if swallowed. Their vapours are also harmful. They may
irritate eyes and can be absorbed through the skin. Failure
to follow these instructions can result in property damage,
personal injury, or death.
PVC & CPVC VENT SYSTEM:
PolyPro
®
InnoFlue
®
Primers, cleaners, solvents, and cements are available for
PVC and CPVC pipe/fittings. When cementing the pipe/fit-
tings, make sure to use only materials approved for the type
of pipe/fittings to be installed and in all cases, follow the vent
pipe/fittings manufacturers joining instructions. Never use
all-purpose cements, commercial glues, and adhesives to join
PVC or CPVC pipe/fittings.
1) Cut pipe ends squarely, removing all burrs and dirt.
2) Dry fit the pipe/fitting to be connected to make sure they fit
properly.
3) Clean the pipe/fitting with the proper primer or cleaner.
4) Apply a thin coat of cement to the fitting, avoiding puddling
inside.
5) Apply a liberal coat of cement to the vent pipe, leaving no
voids.
6)
QUICKLY
assemble parts while cement is fluid! If you
wait too long, re-coat pipe/fitting.
7) Push the vent pipe completely into the coupling, turning as
it goes until it bottoms out.
8) Hold pipe and fitting together for thirty (30) seconds. Then
carefully clean off any excess material with a cloth. Allow con-
nections a sufficient time to cure before disturbing.
9) Remember that vent pipes must be adequately and
securely suppported.
POLYPROPYLENE PIPE:
PolyPro
®
InnoFlue
®
PolyPro
®
InnoFlue
®
Follow the vent pipe manufacturer installation instructions
to assemble the vent pipe. Make sure to secure the vent
pipe sections together using the mean (connector ring or
locking band) as specified by the vent pipe manufacturer.
Vent Termination Through-The-Wall
PVC & CPVC VENT SYSTEM:
PolyPro
®
InnoFlue
®
Two (2) 90-degree PVC elbows are supplied with the water
heater and shall be installed at the end of the vent and
air intake piping to serve as the termination for through-
the-wall installation when the vent system is built with
PVC pipes. If CPVC is used to build the vent system, use
90-degree CPVC elbows that are approved to be used with
the vent system. A wire mesh screen must be installed in
the termination elbows.
POLYPROPYLENE VENT SYSTEM:
PolyPro
®
InnoFlue
®
PolyPro
®
InnoFlue
®
A 90-degree polypropylene elbow approved to be used with
the vent system shall be used as the termination elbow for
through-the-wall installation. Be sure to remove the wire
mesh screen that was supplied with the 90-degree PVC
elbow and insert it into the polypropylene elbow. Push the
screen until it locks in place inside the elbow.
Vent Termination Through-The-Roof
PVC & CPVC VENT SYSTEM:
PolyPro
®
InnoFlue
®
Two (2) 90-degree PVC elbows are supplied with the water
heater and shall be installed at the end of the vent and
air intake piping to serve as the termination for through-
the-roof installation when the vent system is built with
PVC pipes. If CPVC is used to build the vent system, use
90-degree CPVC elbows that are approved to be used with
the vent system. A wire mesh screen must be installed in
the termination elbows.
POLYPROPYLENE VENT SYSTEM:
PolyPro
®
InnoFlue
®
PolyPro
®
InnoFlue
®
A 90-degree polypropylene elbow, approved to be used
with the vent system shall be used as the termination
elbow for through-the-roof installation. Be sure to remove
the wire mesh screen that was supplied with the 45-degree
PVC elbow and insert it into the polypropylene elbow. Push
the screen until it locks in place inside the elbow.
DANGER
WARNING
CAUTION
AVERTISSEMENT
ATTENTION
In freezing weather, check for snow accumulation around
the water heater vent and air intake terminals where they
pass through the outside wall. The open ends of the termi-
nals must be installed at least twelve (12) inches (30 cm)
above the highest anticipated snowfall to prevent blockage
by snow.
DANGER
WARNING
CAUTION
AVERTISSEMENT
ATTENTION
Check that all openings and gaps in the outside wall near
and around where the vent and air intake pipes pass
through the exterior wall are sealed to prevent infiltration
of combustion products into the building.