Wiring Diagram

For the 12~24VDC/AC operation only

12~24VDC/AC Power supply

“Fail-Safe”

(Power to Lock)

Red

Red

Varistor

(Power input is polarity free)

Yellow

Green

Blue

Access Control Device

N.C. contact

Red

Red

Varistor

12~24VDC/AC Power supply

(Power input is polarity free)

“Fail-Secure”

(Power to Open)

Yellow

Green

Blue

Access Control Device

N.O. contact

NOTE: 

The varistor (or diode) must be connected across the terminals as shown above. This protects the electromechanical

lock from spikes and surges.

ø5.0

ø5.0

ø5.0

30

19.5

30

86.5

318

275

25

30

19.5

ø5.0

ø18.0

ø11.0

150

206

Alignment CL

Cut on dotted line

Alignment CL

Alignment CL

Door leaf edge

Door leaf edge

Template

Unit:mm

Butt Splice (IDC) Connector

Using crimper or pliers and pressing the header of 
connector down to even position.

62mm cylinder  for max 

42mm  door leaf

72mm cylinder  for max 

52mm  door leaf

ø5.0

ø5.0

25

28

150

28

124

250

30

30

5

6

7

8

30

ø5.0

ø5.0

1

2

3

4

Unit:mm

Installation Instructions

Do

or l

ea

f

Doo

r F

ram

e

Door Loop
(Optional)

(Cylin

der 

not in

clude

d)

Align the center line (CL) of the 

Alignment CL

Fram

e

Do

or L

eaf

Do

or L

eaf

Cut out mortise holes for the lock 

Tighten the fixing lugs with 

screws.

Drill and cut the hole for the lock 

Connect power cable to the lock 

Attach the cover plates for the

 Install the cylinder

Fix the strike plate.

The door loop protects the wiring 

from damage at the door hinge.

Attention! Please ensure that the 

direction of the template is correct

Doo

r Fra

me

lock body template with the CL of 

the door leaf. Ensure the CL of the 

strike plate template matches the lock 

body CL as closely as possible.

body and strike plate and drill holes 

according to the templates.

cylinders as shown in the template.

and test before screwing to the 

door leaf.

cylinder lock 

Optional Lock Bolt Sensor (LBS) Status Output:
With LBS output:ML-300-SW
Without LBS output:ML-301-SW

Reviews: