background image

Regular Installation

Installation Instruction:

Close the door and make sure the door and the door frame are at the same

Drill 9.4mm holes
for M6 Blind Nuts.

allen wrench

Insert the Blind Nut into
fixing screw and separate
holes.

Use the allen wrench . to
slowly tighten the Blind Nut.
(Don’t tighten the nuts too firmly.)

Keep wrenching the Blind
Nut so that it remains

permanently fixed in the
frame.
Remove the tool.

12mm CABLE HOLE

9.4mm BLIND NUTS

MAGNET ASSEMBLY

9.4mm BLIND NUTS

ARMATURE ASSEMBLY

Door

Frame

Important Notes

The electromagnetic lock is fail-
safe and will require a power supply
unit equipped with battery back up for
fear that power failure may increase
security risks.

Do not install a diode or MOV in 
parallel with any magnetic lock. A 
diode will cause a delay when
releasing the door.

Apply a light coat of a silicon
Iubricant to prevent the maglock
from rusting. Wipe off the excess.

Do not strand power wires and signal
wires in the same cable or conduit.

Trouble Shooting

Problem

Door does not lock

No power

Reduced holding froce

Poor contact between electromagnet and
armature plate

Low voltage or incorrect voltage setting

Sensor output is not functioning

A secondary diode was installed across

the electromagnet

Misalignment between the armature plate

and its magnet

Possible Cause

Solution

Make sure the wires are securely tightened to the correct terminal block 

Check that the power supply unit  is connected and operating properly

Make sure the lock switch is wired correctly 

Make sure the surface of the armature plate is in good shape

Make sure the rubber washer is inserted behind the armature plate

Make sure the contact surfaces of the electromagnet and armature plate are clean
and free from dust

Check the setting of power input volume

Check the settings of the voltage / current volume on the terminals of the maglock

Remove any diode installed across the magnet for “spike”
suppression. (The magnet is fitted with a metal oxide varistor to prevent back EMF)

Check the faces of armature plate and the maglock are aligned face-to-face

level of height; otherwise, it is necessary to add extra iron boards to make

Stick the templates to the corresponding positions on the door and frame. 

Drill the holes for cables and screws according to the templates.

Fix the blind nuts (see illustration below) to secure the maglock.

Wire the maglock.

Fix the armature plate. Plug in the maglock. Close the door and test the

Power

Input

Power

N.O.

COM.

N.C.

Power

Input

SPDT relay

3A/12VDC

F

2

1

3

4

5

6

the door or the door frame at the same level.

installation.)

(Make sure the gap between the door and frame is within the limit set by

holding force. Add rubber washers if necessary to adjust the gap between

 the armature plate and maglock.

wrench

Copyright © All Rights Reserved.   P-MU-PH-450-900  Ver.A  Publish: 2011.07.28

Reviews: