GK800 Series
Electric Strike
Installation Instruction
Copyright © All rights reserved. P-MU-GK800-1224 Published: 2020.11.23
Wiring Diagram
Dual Voltage (12/24V)
N.C. contact output: door open
N.O. contact output: door closed
Door status output; SPDT:1A/125VAC
N.C. contact output: door open
N.O. contact output: door closed
Blue: N.O.
Gray: COM.
Yellow: N.C.
Version Adjustment:
Control Mode
Butt Splice (IDC) Connector
Place the wire inside the connector and use pliers
to press down on the head of the connector evenly.
Operating Voltage: 12/24VDC
Current Draw: 300mA/12VDC
150mA/24VDC
Operating Temperature: 32˚F to 120˚F
(0˚C to 49˚C)
Humidity: 0% to 85% Non-condensing
Life Rating of Solenoid: over 500,000 cycles
Latch Throw: GK800/GK810 series:12 mm
GK850 series:15 mm
GK880 series:19 mm
Keeper width: GK800/GK810 series:44 mm
GK850 series:43 mm
GK880 series:44.5 mm
Material: Zinc alloy main stand
Stainless steel faceplate
Weight (approx.): GK800 series 250g
GK810 series 290g
GK850 series 280g
GK880 series 370g
Specification
Step1: Fail-secure
Remove the plug and take out
the round screw.
Step2: Fail-safe
Turn the round screw upside
down (180°).
Step3:
Put the screw and the plug
back.
Fail-safe when
“1” facing up
Fail-secure when
“2” facing up
GK880
GK850
GK810
80
20.20
2.50
25.40
250
44
40
74
12
4.50
25
14
80
20.2
0
3
37.70
43
44.50
123.80
31.80
4.90
19.30
GK800
44
160
14
6.50
235.4
31
30.5
39.25
34
19
28
3
43
149.50
34
136
37.7
GK800M
GK810M
GK850M
GK880M
(GK800M/810M/850M/880M with door status output.)
12VDC
+
-
Red
Black
(Polarity Insensitive)
12VDC
Control Device
24VDC
+
-
White
Black
(Polarity Insensitive)
Control Device
Dual Voltage (12V/24V)
9'&
%ODFN
5HG
:KLWH
*UHHQ
3RODULW\)UHH
&RQWURO'HYLFH
9'&
:KLWH
*UHHQ
%ODFN
5HG
3RODULW\)UHH
&RQWURO'HYLFH
24VDC