P-MU-EASIPROX  Ver. F  Published on 2011.02.14                                                                      Page: 2/ 4

 

IV. Wiring Diagram 

 

 

 

For DC use only

For AC/DC

 

 

 
Note: 

1. It is suggested to use #22~26 AWG insulation wire. 
2. It is suggested to use a linear power supply unit to prevent the reduction of reading range. 
3. The door strike or relay must have a varistor or a diode across the door strike terminals to suppress  
    the back EMF of the strike. Failure to do so will damage the relay contacts and electronic components 
    , or even burn the controller. 
4. Exit button is at N.O. contact. 
 

 
V. Operation Instruction 

1. Set Master Card 
    Yellow and Green LED flash indicates that the memory is empty. The first card read by the reader  
    will be the Master Card. 
    Read the Master Card (Yellow LED stay on), enter standby mode 
    Note: The same Master Card can be used on more than one reader.  
 
2. Add new cards 
   1. Read Master Card once (Green LED stay on for 3 seconds, then flash), enter adding card mode 
   2. Read the new card(s) (relay active 

 successfully adding the new card)  

   3. Read Master Card once (Green LED off, Yellow LED stay on), back to standby mode 
   Note: It is suggested to use the card of ABA form codes and make a list of the cards added to the      
   reader. 
 
3. Delete cards 
    1. Read Master Card twice within 2 seconds (Red LED stay on for 3 seconds and flash), enter    
        deleting card mode 
    2. Read the card(s) (Green LED stay on 

 successfully delete cards) 

    3. Read Master Card once (Red LED off, Yellow LED stay on), back to standby mode 

Red 12 

VDC 

 (polarity free) 

Green Exit 

Button 

Red 12 

VDC 

 (polarity free) 

Green Exit 

Button 

White 

Com. 

Black 

Clear all memory 

Yellow N.C. 

Black 

Clear all memory 

Blue N.O. 

 

 