background image

 

Copyright Gianni Industries, Inc. All Rights Reserved.  
P-MU-DG25  Ver. D  Publish:2010.08.12                                                             Page: 3/ 3

 

 

To Program Relocking Timer 

(at programming mode)

 

A. Relay 

1

Press

「*

100

(relay 1) or 

*200

(relay2) , Followed by the number of 

seconds the relay should open

05

=5 seconds

01 ~99 = seconds

beep

enrolled 

 Press 

#

 to exit from the programming mode. 

B. Enter

00

Sets the relay to latching mode.

 

(Correct code entered opens the relay, 

and the relay stays open until the correct code is entered again). 

 

  Changing the Master codes: (at programming mode) 

        

Enter

「*

000

Followed by the new 5 digit master code

beep

enrolled

Enter 

#

 to exit from the programming mode. 

 

  Master Code reset to Factory default 

12345

 

Insert the jumper P1

 1-2 position

5 beeps

Reset successful. 

 

5. Wiring diagram: 

 

 

For DC use only

For AC/DC

 

 

Note: 

 

It is suggested to use a linear power supply unit to prevent reading range reduction at 
the card reader. 

 

The suggested wire gauge is #22~26 AWG. 

 

The door strike or relay must have a varistor or a diode across the door strike terminals 
to suppress the back EMF of the strike-failure to do so will damage the relay contacts 
and electronic components , or even burns the controller. 

 

Warranty:

 

The product is warranted against defects in material and workmanship while used in normal 
service for a period of 1 year from the date of sale to the original customer .GEM policy is one 
of continual development and improvement , therefore GEM  reserves the right to change 
specifications without notice. 
 

Reviews: