Output 2 relays  (Dry contacts: N.O./N.C./Com.

 

Relay Strike Time 01~99 seconds or Toggle Mode (00) / Relay 1 (*100) , Relay 2 (*200) 

Relays Electric Current 3A/120VAC , 3A/24VDC

 

Relay Activation Time 

Strike Time: 1~99 seconds

adjustable

 

Strike mode: Access Timer or Latch 

Memory Volume 

49+50 PIN codes 

Relay 1 is controlled by 001~049 user slots 
Relay 2 is controlled by 050~099 user slots 

EPROM 

Non-volatile memory, System will retain all programs and codes after a total   
loss of power. 

Finish Stainless steel brushed housing 

                Ambient Humidity 0~95% relative humidity non-condensing 

Operating Temperature -20

°

C~+70

°

C                                   

 

 
 

3.  The indicator signal chart: 

Sound and LED indicator:  

Green LED

  

Power on, stand-by  

Red LED

 

Relay 1 activated 

LED signal 

Yellow LED 

Relay 2 activated 

1 Beep 

Effective PIN codes 

2 Beeps 

Entering 

Exiting from the programming mode 

3 Beeps 

Incorrect operation 

Sound signal 

5 Beeps 

Master Code reset to Factory default 

12345

 

 
 

4. Operation Instruction: 

 

  Enter Program Mode:  

1.  Compose twice the master code (Factory default is 

12345

)  

 2 beeps 

 you are now in the "program mode". 

2.  After 60 seconds if you have not entered any codes or data, the system will 

automatically exit from the programming mode. After 32 wrong codes attempts at ,  
system the will be lockout for 60 seconds. 

 

  Exit from the programming mode: 

1. Press

#

 to exit from the programming mode. 

  Add PIN codes (at programming mode) 

Enter the slot position code 

「*

001~

099

????? Input 5 digit PIN code

 (beep) 

enrolled 

repeat

, or, 

Press 

#

 to exit from the programming mode. 

Note 1:

 The codes

00000

,

12345

or master code can not be used as PIN code. 

Note 2:

 Relay 1 is controlled by 001~049 user slots, Relay 2 is controlled by 050~099 

user slots 

 

  To Delete a User Code

(at programming mode) 

        

Press the slot position code of your choice to delete (example "006") 

Press

「*

006

00000

beep

delete

Press

#

 to exit from the programming mode.

 

       

 

 