Giandel PS-2200KAR User Manual Download Page 5

7

8

7. USING THE POWER INVERTER

1.  Check the output voltage and capacity of the battery. The battery (s) should match the 

voltage of the inverter and have enough capacity for the load. See Section E for more 
information.

2.  Connect your inverter to your battery bank and do not to reverse the polarities of the 

connection. See Section F.

3.  Press the power switch button on your inverter for 0.5 seconds and a green LED will 

light up indicating that the inverter is on. 

4.  Before plugging anything into your inverter, make sure the appliance you are trying to 

power is shut OFF, then plug it into the AC outlet of your inverter and power on your 
appliance.

5.   Once  finished  using  the  inverter,  turn  off  your  electrical  appliance  and  the  inverter. 

The indicator lights should be off. 

6.  The  cooling  fans  inside  the  inverter  do  not  work  until  the  case  temperature  reaches 

approximately 104°F.

7.  If you do not plan to use the inverter for a long period of time, disconnect it from your 

battery  bank.  Leaving  the  inverter  on  and  connected  for  long  periods  of  time  may 
harm the equipment and over discharge the battery.

8.  The USB port on this unit can provide a stable line of 5V DC current. It will auto detect 

your  device's  max  charging  current from  0  to  2.4A  current. Be  sure  to  double  check 
your device to make sure it doesn't exceed these requirements.

8. SOFT START TECHNOLOGY

The  soft  start  technology  built  into  this  inverter  protects  the  unit  from  delivering  too 

much AC  power  at  once  by  gradually  increasing  the AC  voltage  pushed  out.  To  make 
sure that you are utilizing this feature, turn on the appliance being used before turning 
on the inverter. This is especially necessary for equipment that has an inductive load or 
electrical motor.

9. OUTPUT VOLTAGE & WAVEFORM

The  electrical  waveform  output  of  this  inverter  is  a  pure  sine  wave,  which  has  the 

same quality as utility and/or domestic power. This type of waveform is suitable for most 
electrical  devices,  appliances  and  tools.  This  pure  sine  wave  unit  provides  more 
capabilities than modified sine wave inverters because it is a cleaner form of power. 

The  pure  sine  wave  also  effectively  reduces  the  noise  produced  while  using 

appliances.

10. LED DISPLAY

While the inverter is working, the input voltage and output power will be shown on the 

LED display screen by turns. When the inverter goes into protection, the following code 
may be shown:

1. LO means the inverter is in under voltage protection.

2. HI means the inverter is in over voltage protection.

3. OL means the inverter is in overload protection or short-circuits protection.

4. OH means the inverter is in OVER HEAT protection.

11. PROTECTION FEATURES

1.  Input  under-voltage  alarm:  When  the  input  DC  voltage  is  lower  than  10.1V  (20.2V), 

the buzzer will whistle intermittently to remind that the inverter will go into the under 
voltage protection. Pay attention to save the data if you are using computer. 

2. Under voltage protection: The inverter will automatically shut down when the input DC 

voltage is lower than 9.8V(19.6V).The buzzer will whistle continuously and the green 
light is off, red light is on. Please turn off the inverter and use it after recharging the 
battery.  

3. Over voltage protection: The inverter will automatically shut down when the input DC 

voltage  is  higher  than  16V(32V).The  buzzer  will  whistle  continuously  and  the  green 
light is off, red light is on. Please turn off the inverter and adjust the input voltage to 
the admissible range.

4. Overload protection: The inverter will automatically shut down when the load is higher 

than  the  rated  power. The  buzzer  will  whistle  continuously. Turn  off  the  inverter  and 
resume to normal operation after taking away the excessive load.

5.  Short-circuit  protection:  The  AC  output  will  be  automatically  shut  down  when  short 

circuited. It will automatically reset after the problem is solved.

6. Thermal protection: The unit will get bot during operation. If the temperature is higher 

than  149°F,  the  inverter  will  automatically  shut  down.  Then  the  buzzer  will  whistle 
continuously and the green light is off, red light is on. Please turn off the inverter, and 
continue using it after the temperature goes back to normal naturally. Meanwhile find 
out the factors causing the fault, such as ventilation, ambient temperature, vent, load 
power and so on. It can avoid similar things from happening again.

**NOTE**  The  numbers  in  the  parenthesis  are  for  24V  models.  In  the  case  of  over 

voltage, under voltage and thermal protection, the inverter will shut down. When the 
inverter is in the OFF position, the inverter doesn't consume battery current.

12. HOW TO CHANGE FUSE

1.  Firstly  disconnect  the  inverter  and  external  batteries,  solar  panels,  load  etc  all  the 

connections.

2. Unscrew the side plate screws and pull out the bottom plate.

3. Use pliers to clamp car fuse inside the product, and pull out .

4.Replace the same specifications of the car fuse, and then install the bottom and side 

panels, and screw well.