Giacomini GE556-5 Datasheet / Operating Instructions Download Page 6

6

Giacomini S.p.A.

Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia

 [email protected]

 +39 0322 923372 - giacomini.com

 Operation

Filter

Probe housing for thermal energy meter

C

Brass spacer for domestic cold water meter

Heat exchanger

E

Brass spacer for thermal energy meter

Thermostatic head with temperature probe

Probe housing for differential pressure control valve

Mechanical priority valve

Check valve

H

Brass spacer for domestic hot water meter

Manual air vent valve

Compact differential pressure control valve (GE556Y530 kit)

or double regulation diff. press. control valve (GE556Y532 kit)

Presetting valve (kit GE556Y544)

Water hammer arrestor

R

Circulator for domestic hot water recirculation

A

Domestic cold water outlet

B

Domestic cold water inlet

C

Domestic hot water outlet

D

Primary inlet

E

Primary outlet

F

High-temperature heating delivery

G

High-temperature heating return

H

Domestic hot water recirculation

 WARNING.

 When recirculation kit (GE556Y564/565) is included, install the 

additional unit output for domestic cold water (GE556Y561) and reverse the 
domestic cold water inlet/outlet flows (A and B).
It is also necessary to provide an expansion tank suitably sized according to the 
volume of the recirculation system.

PRIMARY CIRCUIT: inlet: (D) and outlet (E).

 

The primary circuit includes two zones: one for heating control and the other for domestic 

hot water production. The primary circuit includes a filter, a housing to install the probe of the differential pressure control valve, a 
mechanical priority valve, a manual air vent valve, a brass spacer and a differential pressure control valve.

The brass spacer (Components - Ref. 6) can be replaced with a thermal energy meter by installing its temperature probe in the 

matching housing (Components - Ref. 2).

The water from the boiler room enters the HIU and is generally channeled towards the heating secondary circuit.

When there is a demand for domestic hot water, the priority valve diverts the primary fluid towards the heat exchanger; a thermostatic 
head controls and sets the required flow rate (when kit GE556Y522 is included).

DHW: cold water inlet (B), cold water outlet (A), hot water outlet (C).

 The domestic water circuit includes a mechanical priority valve, 

a check valve, a water hammer arrestor, a heat exchanger, a flow rate controller and a brass spacer (two spacers when kit GE556Y561 
is included). The two brass spacers (Components - Ref. 12 and 15) can be replaced with a domestic cold/hot water meter.
A thermostatic head (when kit GE556Y522 is included) (Components - Ref. 10) controls and sets the domestic hot water temperature.

HIGH-TEMPERATURE HEATING: delivery (F) and return (G).

 The high-temperature heating circuit includes a presetting valve with 

optional installation of a thermo-electric actuator (when kit GE556Y544 is installed).
After  flowing  through  the  mechanical  priority valve,  the  primary  circuit  hot water  is  channeled  directly  into  the  high-temperature 

heating system.

C

H

E

H

D

G

C

E

F

R

B

A

C

H

E

B

D

G

C

A

E

F

C

H

E

H

D

G

C

E

F

R

B

A

C

H

E

B

D

G

C

A

E

F

Summary of Contents for GE556-5

Page 1: ...nd domestic hot water production DHW systems with centralized heat production e g teleheating HIUs GE556 5 are modular as they enable to combine multiple components and create the HIU most suitable fo...

Page 2: ...ow rate of high temperature heating circuit kit GE556Y543 480 l h T 10 C 80 70 C for 5 5 kW WARNING The HIU is suitable for installation in indoor rooms and boiler rooms and use with non aggressive fl...

Page 3: ...ith differential pressure control valve GE556Y564 Unit output for domestic water recirculation with circulator GE556Y513 26 plate exchanger 5 mm insulation GE556Y530 Primary circuit connections with c...

Page 4: ...lve for domestic cold water to be installed on template when optional kit GE556Y561 is included Examples of possible layouts NOTA For the realization of the purchase code of the desired configuration...

Page 5: ...OPTIONAL 14 Flow rate controller 15 Brass spacer for domestic hot water meter DHW 16a Water hammer arrestor 16b Domestic water recirculation kit with circulator kit GE556Y564 or without circulator kit...

Page 6: ...mary circuit includes a filter a housing to install the probe of the differential pressure control valve a mechanical priority valve a manual air vent valve a brass spacer and a differential pressure...

Page 7: ...GE556Y504 Primary connections from top BASIC DOMESTIC WATER CIRCUIT PRIMARY CIRCUIT SECONDARY CIRCUIT OPTIONALS Heat exchangers Control components Insulation Other optionals GE556Y503 Primary connecti...

Page 8: ...UIT SECONDARY CIRCUIT OPTIONALS Heat exchangers Control components Insulation Other optionals GE556Y503 Primary connections from bottom GE556Y511 16 plate exchanger 5 mm insulation GE556Y521 DHW produ...

Page 9: ...ion GE556Y522 DHW production with thermostatic control GE556Y532 Primary circuit connections with double regulation differential pressure control valve GE556Y564 Unit output for domestic water recircu...

Page 10: ...6 plate exchanger 5 mm insulation GE556Y530 Primary circuit connections with compact differential pressure contr valve GE556Y565 Unit output for domestic water recirculation without circulator GE556Y5...

Page 11: ...r recirculation with circulator GE556Y513 26 plate exchanger 5 mm insulation GE556Y530 Primary circuit connections with compact differential pressure contr valve GE556Y565 Unit output for domestic wat...

Page 12: ...ation GE556Y564 with circulator GE556Y565 without circulator GE556Y564 Unit output for domestic water recirculation including circulator GE556Y565 Unit output for domestic water recirculation without...

Page 13: ...onnections with compact differential pressure contr valve GE556Y565 Unit output for domestic water recirculation without circulator GE556Y514 26 plate exchanger 20 mm insulation GE556Y566 Thermostatic...

Page 14: ...ion differential pressure control valve GE556Y564 Unit output for domestic water recirculation with circulator GE556Y513 26 plate exchanger 5 mm insulation GE556Y530 Primary circuit connections with c...

Page 15: ...n and or maintenance remove the metal cover completely tilting it slightly and sliding it off the upper bracket Weight 4 5 kg GE551Y184 HIU locking metal cover NOTE The metal cover can be installed on...

Page 16: ...D E 10000 5000 1000 P mm H 2 o Q l h 100 10 10 100 10000 1000 Kv 1 4 Differential pressure regulation range Primary circuit with thermostatic by pass for DHW production D E 10000 1000 P mm H 2 o Q l...

Page 17: ...C 10000 1000 P mm H 2 o Q l h 100 10 10 100 10000 1000 Kv 0 8 High temperature heating with kit GE556Y544 presetting valve D E G F Presetting valve position 0 5 1 2 3 4 5 6 7 N Fully Open Kv R402PTG...

Page 18: ...5 65 500 24 60 600 27 10 600 28 80 420 21 75 470 22 5 70 540 24 5 65 650 26 12 720 34 80 515 23 75 575 24 70 660 25 5 DHW production with 16 plate exchanger and 15 l min flow rate controller GE556Y51...

Page 19: ...10 C 80 70 C for 5 5 kW DHW production with 16 plate exchanger and 18 l min flow rate controller GE556Y515 GE556Y516 Domestic hot water t 10 50 C Primary circuit working conditions Flow rate l min Fl...

Page 20: ...pes Min 1000 mm For an easier installation the HIU includes 3 4 F flat nuts with adjustable tail pieces 10 mm extension Before fitting the HIU on the wall extend every single adjustable tail piece up...

Page 21: ...288 mm 410 mm 60 mm C D E F Drill the wall in the positions previously measured Use screw anchors fit for the type of wall and weight of the equipment D X mm 207 mm 390 mm 288 mm 410 mm X mm 207 mm 3...

Page 22: ...right corner of the HIU including a terminal strip for electric connection of the circulator optional thermostats and M Bus networks for data centralization Electric data of recirculation kit circula...

Page 23: ...620 749 895 146 60 180 40 60 60 60 432 B D C A E F G 26 HIUGE556Y504withaccessories templateGE551Y088 774 921 829 485 200 CoverGE551Y184 template GE551Y087 879 673 788 477 189 Insulation GE556Y552 tem...

Page 24: ...de l autorit locale concernant l emplacement des plates formes cologiques appropri es pour recevoir le produit pour sa destruction et son recyclage correct ult rieur Il convient galement de rappeler...

Reviews: