3.  Safety instructions 

This device was designed and tested considering the safety regulations for electronic measuring devices. 
Faultless operation and reliability in operation of the measuring device can only be assured if the General 
Safety Measures and the devices specific safety regulation mentioned in this 

user’s manual are considered. 

1.  Faultless operation and reliability in operation of the measuring device can only be assured if the device 

is used within the climatic conditions specified in the chapter “Specifications“. 

2.  By faulty handling of the interface converter a damage of the device cannot be excluded. Likewise a 

damage of your attached device is possible.  

In such case we cannot assume any warranty.

 

The manufacturer will not assume any warranty for damages to other devices resulting by use of the 
interface converter. 

3.  Standard regulations for operation and safety for electrical, light and heavy current equipment have to be 

observed, with particular attention paid to the national safety regulations. 

4.  When connecting the device to other devices (e.g. the PC) the interconnection has to be designed most 

thoroughly, as internal connections in third-party devices (e.g. connection of ground with protective 
earth) may lead to undesired voltage potentials. 

5.  The device must be switched off and must be marked against using again, in case of obvious 

malfunctions of the device which are e.g.: 

 visible damage 

 no pre-scripted working of the device 

 storing the device under inappropriate conditions for longer time 

When not sure, the device should be sent to the manufacturer for repairing or servicing. 

6.  Attention: 

Do not use this product as safety or emergency stopping device or in any other application 

where failure of the product could result in personal injury or material damage. Failure to comply with 
these instructions could result in serious injury and material damage. 

7.  This device must not be used at potentially explosive areas! The usage of this device at potentially 

explosive areas increases danger of deflagration, explosion or fire due to sparking. 

8.  This device is not constructed for use in medical applications. 

9.  This device must not be run with a defective or damaged power supply unit. Danger to life due to 

electrical shock! 

4.  Disposal notes 

 

The device must not be disposed in the regular domestic waste. 
Send the device directly to us (sufficiently stamped), if it should be disposed. 
We will dispose the device appropriate and environmentally sound. 

 

5.  Installation 

 

For installation of the device drivers a user account with an administrator-authorisation is required. 
If you haven’t an appropriate authorisation please consult your system administrator. 

If you already have a device installed with the same USB-Chipset the adaptor will be installed 
automatically, if not the system will request you to install the driver. 

 

If the adaptor is correctly installed on your system you have, for application with our 
software, a new additional COM-Port is available. 

 

 

Summary of Contents for GREISINGER USB 5200

Page 1: ...ROUP Greisinger GHM Messtechnik GmbH Hans Sachs Str 26 93128 Regenstauf GERMANY Tel 49 9402 9383 0 info greisinger de www greisinger de Interface converter Installation and operating manual USB 5200 WEEE Reg Nr DE 93889386 ...

Page 2: ...w to find out the used version of the driver 5 1 Intended use The adapter contains 3 functions electrically isolated interface converter for the connection of a GMH 5xxx to the USB interface of your PC electrically isolated instrument power supply for the GMH 5xxx Connection terminal for the analog output of the GMH 5xxx GMH 5xxx with analog output function required 2 General advice Read through t...

Page 3: ...of the device which are e g visible damage no pre scripted working of the device storing the device under inappropriate conditions for longer time When not sure the device should be sent to the manufacturer for repairing or servicing 6 Attention Do not use this product as safety or emergency stopping device or in any other application where failure of the product could result in personal injury or...

Page 4: ...available after successful initialisation of the adaptor by your PC Assignment analog output socket 5 analog output 6 GND Analog output contact are direct wired with pin of the device cable forward resistance 10 Ohm Power Supply via USB interface Operating temperature 0 50 C Storage temperature 20 70 C Housing Dimensions 56 x 31 x 24 mm L x W x D only housing Cable length USB approx 30 cm GMH 5xxx...

Page 5: ...ange the COM port of the adaptor Make sure that the adaptor is connected start the Device Manager and open the submenu Ports COM LPT If the installation was successful there will be the entry CP210x USB to UART Bridge Controller COMx in which the x after the Com indicates the available COM port i e COM4 Open the features of this connection by a double click go to Port Settings and then click there...

Page 6: ...S61 0 01 6C 03 page 6 of 6 ...

Reviews: