GHM Delta OHM HD2304.0 Operating Manual Download Page 16

 

HD2304

 

-   16   -

 

V1.8

 

W ARN I N GS 

1.  Do not  expose t he probes t o gases or liquids t hat  could corrode t he m at erial of t he 

sensor or t he probe it self. Clean t he probe carefully aft er each m easurem ent . Som e 
pressure probe m odels  are suit able for m easurem ent  of non- corrosive gases or air 
and dry and not  liquid only:  check t he m em brane com pat ibilit y wit h t he plant  fluid. 

2.  Do not  bend t he probe connect ors or force t hem  upward or downward. Do not  bend 

or force t he cont act s when insert ing t he probe connect or int o t he inst rum ent . 

3.  Do not  bend, deform  or drop t he probes, as t his could cause irreparable dam age. 

4.  Always select  t he m ost  suit able probe for your applicat ion. 

5.  Do not  use t he t em perat ure probes in presence of corrosive gases or liquids. The 

sensor cont ainer is m ade of AI SI  316 st ainless st eel, while t he cont act  probe 
cont ainer is m ade from  AI SI  316 st ainless st eel plus silver. Avoid cont act  bet ween 
t he probe surface and any st icky surface or product  t hat  could corrode or dam age it . 

6.  Above 400° C and below  –40° C, avoid violent  blows or t herm al shocks t o Plat inum  

t em perat ure probes as t his could cause irreparable dam age. 

7.  To obt ain reliable m easurem ent s, t em perat ure variat ions t hat  are t oo rapid m ust  be 

avoided. 

8.  Tem perat ure probes for surface m easurem ent s ( cont act  probes)  m ust  be held 

perpendicular against  t he surface. Apply oil or heat - conduct ive past e bet ween t he 
surface and t he probe in order t o im prove cont act  and reduce reading t im e. 
What ever you do, do not  use wat er or solvent  for t his purpose. A cont act  
m easurem ent  is always very hard t o perform . I t  has high levels of uncert aint y and 
depends on t he abilit y of t he operat or. 

9.  Tem perat ure m easurem ent s on non- m et al surfaces usually require a great  deal of 

t im e due t o t he low heat  conduct ivit y of non- m et al m at erials.  

10. 

Pr obe s a r e  not  insula t e d fr om  t he ir  e x t e r na l ca sing

;  be very careful not  t o 

com e int o cont act  wit h live part s ( above 48V) . This could be ext rem ely 
dangerous for t he inst rum ent  as well as for t he operat or, who could be 

elect rocut ed. 

11. Avoid t aking m easurem ent s in presence of high frequency sources, m icrowave 

ovens or large m agnet ic fields;  result s m ay not  be very reliable. 

12. Clean t he probe carefully aft er use. Clean t he probe pressure cham ber carefully. 

Avoid deposit s or incrust at ions left  by t he fluid com ing int o cont act  wit h t he 
m em brane, as wit h t im e t his could cause m easurem ent  errors.  

13. Avoid insert ing nails or spikes int o t he pressure cham ber as t he m em brane could be 

unint ent ionally t orn.  

14. I n order t o fix t he probes, use a suit able fixed wrench, and possibly sealing gasket s.  

15. 

Gr e a t  a t t e nt ion m ust  be  pa id w hile  inst alling t he  pr obe s in cont aine r s a nd 

t ube s unde r  pr e ssur e . Also pa y  a t t e nt ion t o t he  pr obe s’ bot t om  
sca le . I n a ddit ion t o t he  ir r e par able  dam a ge , it  ca n e v e n ca use 
se r ious physica l da m a ge t o bot h t he  ope r a t or  a nd t hings. Be for e  t he 

pr obe  a  st op va lve  should a lw a ys be  pr e se nt . Ensur e  t ha t  t he  pla nt  is not  
subj e ct  t o a bnor m a l or  une x pe ct e d de pr e sse d fluid fluct ua t ions. 

 

16. The inst rum ent  is wat er resist ant  and I P67, but  should not  be im m ersed in wat er. 

The probe connect ors m ust  be fit t ed wit h sealing gasket s. Should t he inst rum ent  fall 
int o t he wat er, check for any wat er infilt rat ion. Gent ly handle t he inst rum ent  in such 
a way as t o prevent  any wat er infilt rat ion from  t he connect ors’ side. 

Summary of Contents for Delta OHM HD2304.0

Page 1: ...Operating manual Manometer Thermometer HD2304 0 www deltaohm com English Keep for future reference...

Page 2: ...R 14 I NSTRUMENT SI GNALS AND FAULTS 1 5 W ARNI NGS 1 6 I NSTRUMENT STORAGE 1 7 LOW BATTERY W ARNI NG AND BATTERY REPLACEMENT 1 8 WARNING ABOUT BATTERY USE 18 NOTES ABOUT W ORKI NG AND OPERATI VE SAFE...

Page 3: ...d with the SICRAM automatic detection module with the factory calibration settings already being memorized inside The units of measurement for the measurable quantities are Pa Pascal hPa hectopascal k...

Page 4: ...HD2304 4 V1 8 Manom eter Therm om eter HD2 3 0 4 0...

Page 5: ...the measurement during normal operation in the menu increases the current value 8 UNI T MENU key it allows selection of the unit of measurement when pressed together with the DATA key it allows to op...

Page 6: ...for a few seconds starts an Auto test including the detection of the probe connected to the input and sets the instrument ready for normal measurement The following is displayed MIN cm min s 2 3 m m...

Page 7: ...y pressing this key a third time the average AVG value is displayed The acquisition frequency is once a second The MAX MIN and AVG values remain in the memory until the instrument is on even after exi...

Page 8: ...measurement unit C Celsius degrees F Fahrenheit degrees MENU the menu includes the Probe Type item This item displays the type of probe connected to the instrument s input see chapter xx the menu is o...

Page 9: ...e between the current value and that measured on pressing the key The REL message is displayed on the left To return to the normal measurement press the key again once the MENU has been opened with th...

Page 10: ...bs absolute are displayed alternately in the secondary line temperature probes Pt100 complete with SICRAM module the Auto message is displayed in the central part of the display direct 4 wire Pt100 te...

Page 11: ...askets and joints The threaded connection is protected by a plastic cap Put it back after use as it protects the pressure cell from foreign bodies I MPORTANT Ensure the probe s bottom scale is higher...

Page 12: ...sor is housed in the end part of the probe NOTE when measuring the temperature on frozen blocks it is convenient to use a mechanical tool to bore a cavity in which to insert the tip probe In order to...

Page 13: ...i Pt1000 Ni1000 Not Used Caution Before welding pass the probe cable through the fairlead and gasket 6 Weld the wires as shown in the table Sensor Board connection Jum per to close Pt100 4 wires 4 JP4...

Page 14: ...rs have to be soldered as indicated in the figure on the left In order to use this type of probe it is necessary to set up the menu item Probe Type as described at page 10 The P100 probe is recognized...

Page 15: ...specific instrument SYS ERR Instrument managem ent program error Contact the instrument s supplier and communicate the numeric code reported by the display CAL LOST Program error it appears after tur...

Page 16: ...perform It has high levels of uncertainty and depends on the ability of the operator 9 Temperature measurements on non metal surfaces usually require a great deal of time due to the low heat conducti...

Page 17: ...ent in places where humidity is high the instrument may be exposed to direct sunlight the instrument may be exposed to a source of high temperature the instrument may be exposed to strong vibrations t...

Page 18: ...e instrum ent back on To replace the batteries proceed as follows 1 switch the instrument off 2 unscrew the battery cover counter clockwise 3 replace the batteries 3 1 5V alkaline batteries type AA 4...

Page 19: ...tional safety of the instrument can only be guaranteed under the environmental and electrical operating conditions that are in specified in chapter TECHNICAL CHARACTERISTICS Do not use or store the pr...

Page 20: ...house temperature 25 65 C Working relative humidity 0 90 RH without condensation Protection degree of the case I P6 7 Power Batteries 3 1 5V type AA batteries Autonomy 200 hours with 1800 mAh alkaline...

Page 21: ...MBD 0 25 FSO 0 60 C Tube 5 mm TP704 100MBGI 0 25 FSO 30 80 C BSP 200 mbar 400 mbar 0 1 mbar TP705 200MBD 0 25 FSO 0 60 C Tube 5 mm TP704 200MBGI 0 25 FSO 30 80 C BSP 400 mbar 1000 mbar 0 1 mbar TP704...

Page 22: ...I 5 Imm ersion 50 C 400 C TP4 7 2 I 1 0 Imm ersion 50 C 400 C TP4 9 A I Imm ersion 70 C 250 C TP4 9 AC I Contact 70 C 250 C TP4 9 AP I Penetration 70 C 250 C TP8 7 5 I Globe thermom eter 150 mm 30 C...

Page 23: ...tration probe sensor Pt100 Stem 4 mm length 150 mm Cable length 2 metres TP4 7 4 C O Contact probe sensor Pt100 Stem 4 mm length 230 mm contact surface 5 mm Cable length 2 metres TP4 7 5 A O Air probe...

Page 24: ...ect 4 wires Probe s stem 3 mm length 70 mm 4 wire connection cable with connector length 2 metres TP47 Only connector for probe connection Pt100 direct 3 and 4 wires Pt1000 and Ni1000 2 wires Delta OH...

Page 25: ...HD2304 25 V1 8 NOTES...

Page 26: ...HD2304 26 V1 8 NOTES...

Page 27: ......

Page 28: ...anty included in the manual of the product For any dispute the competent court is the Court of Padua The Italian law and the Convention on Contracts for the International Sales of Goods apply TECHNI C...

Reviews: