5.2 

Operation/maintenance 

The  devices  operate  with  pure  medium  free  of repairs. We recommend applying  a filter  for  unclean 
medium.  With  the  device  WR1  there  is  the  additional  possibility  to  clean  the  sight  glass  with  an 
internal wiper. 

The technical information can be found in the product information. This is included with 
the product or may be downloaded at http://www.ghm-messtechnik.de/en/products/b-
sensors-and-instrumentation/b2-flow/rotor-inline-model.html#c4558.
 

  Filter TYPE ZV 

  Filter TYPE ZE 

Storage 

  Please observe the storage temperature. 

  A desiccant or heating against the formation of condensation is recommended in moist areas. 

Transport 

  Please observe the transportation temperature. 

  Prevent environmental influences such as impacts, blows, dust and vibrations. 

The legal regulations for protecting the environment and our personnel require that returned 
devices  which  have  come  into  contact  with  toxic  and  hazardous  materials  can  be  treated 
with no risks to personnel and the environment. 

Should you return a device to us for evaluation, repair or disposal we ask that you strictly adhere to 
the following regulation: 
 
A return form can be downloaded on our homepage at:  
http://www.ghm-messtechnik.de/en/downloads/ghm-forms.html.

 

 

Acceptance from GHM-Honsberg can only occur if 
 

1.  a filled-out form is provided with each return, 
2.  packing is applied that prevents damage to the device, 
3.  the device is cleaned so that no dangers are present, 
4.  the  filled-out  form  and,  if  necessary  (hazardous  materials),  a  safety  data  sheet  of  the 

measurement medium is applied to the outside of the packaging. 

During  disposal,  a  material  separation  and  recycling  of  the  device  components  as  well  as  the 
packaging must be observed. The legal stipulations and guidelines valid at this point in time must be 
adhered to. 
The  device  may  not  be  disposed  of  in  a  residual  waste  bin.  Should  a  disposal  of  the  device  take 
place, send it directly to us with the return form filled out under point 9. We take over the appropriate 
and professional disposal. 

© GHM-Messtechnik GmbH, Remscheid 
As of: 2014-09-04 

                                            

2

 More information on our accessories can be found in the product information. 

3

 See product information: ambient/transportation temperature 

Technical information 

Accessories

2

 

Device transportation and storage

3

 

Return 

10  Disposal 

11  Disclaimer 

 

All rights reserved, including those pertaining to translation. No portion of this 

operating manual may be reproduced, duplicated or distributed without 

permission from the company GHM Messtechnik in Remscheid. 

Changes reserved. 

 

Summary of Contents for PO

Page 1: ... 4 7 Accessories 4 8 Device transportation and storage 4 9 Return 4 10 Disposal 4 11 Disclaimer 4 This operating manual must be locally stored so that it can always be accessed All procedures described within this operating manual may only be performed by trained personnel authorised by the operator with corresponding protective gear 1 1 Safety signs and symbols Danger signs and symbols are marked...

Page 2: ...s with applications the necessity arises to ensure minimal care e g with lubrication or coolants With the flow devices PO WR1 FR RM and HV a visual flow monitor of fluid media can be facilitated The rotor turbine rotation visualizes the volume flow 2 1 Active principle Rotor The liquid medium enters into the housing and takes the visible arranged rotor in rotation The frequency of the rotor allows...

Page 3: ... is possible When tightening the screw joint the connection must be locked so that no torque is transferred to the body This equipment is designed for low viscosity media Highly viscous medium delays the start of rotor turbine 5 1 Activation Before activation note the limit values stated in the product information such as for pressure stage temperature range or maximum permitted flow If present th...

Page 4: ...ing regulation A return form can be downloaded on our homepage at http www ghm messtechnik de en downloads ghm forms html Acceptance from GHM Honsberg can only occur if 1 a filled out form is provided with each return 2 packing is applied that prevents damage to the device 3 the device is cleaned so that no dangers are present 4 the filled out form and if necessary hazardous materials a safety dat...

Reviews: