background image

Bedienungsanleitung                          
 

As of 04/20/2010 

Seite 13/16 

4.2

 

Open the housing 

Before you can insert a module, it is necessary to open the housing. The steps to do this are described in 
the ProfiLux manual. 

The opened device looks as follows: 

 

In the top left-hand you can see the sockets in which the modules have to be inserted. Next to it on the 
right you can see the connectors of the built-in sensor inputs. In front of the Expansion Box there are the 5 
module cover plates and the more narrow back plate for the – seen from the back – the right side. 

4.3

 

Insert the module 

The new module can be inserted into any slot – except slot Modul 4 (slot nearest to the housing). This slot 
only supports analog measurement cards at the moment.  

When you insert it, pay attention that all contact pins of the module disappear in a socket of the slot. No 
contacts may "remain"! The insertion has to be possible easily and without having to use any force! 

4.4

 

Close the housing 

Now the housing can be closed again. 

First attach the upper housing part again carefully in the right direction (look at interior of cover). Check 
here that front panel and rear plate move properly into the right slots, if necessary correct their position 
slightly. Also here is important: Do not use force! 

Afterwards attach again the 8 covering caps. 

 

 

Summary of Contents for ProfiLux Expansion Box

Page 1: ...User manual for Expansion Box Valid for Firmware version 1 02 and later As of 04 20 2010...

Page 2: ...SION BOX 6 3 ASSIGN THE EXPANSION BOX TO THE PROFILUX 7 3 1 REQUIREMENTS 7 3 2 ASSIGN THE EXPANSION BOX 7 3 3 THE RESOURCES SENSORS AND INTERFACES OF THE EXPANSION BOX 7 3 4 THE SENSORS OF THE EXPANSI...

Page 3: ...sensor Connection option for pH sensor Connection option for a conductivity sensor selectable for salt or fresh water Connection option for a Redox sensor Connection option for 2 level sensors 5 expa...

Page 4: ...o not use force to plug in Important A false connection e g plugging in a light bar plug into a powerbar socket can lead to a destruction of the ProfiLux A possible repair is no warranty case and ther...

Page 5: ...selection switch 6 in order that the conductivity is measured correctly The control cables of dimmable lamps light bars hanging lamps moonlight etc or controllable current pumps are plugged into the...

Page 6: ...ox has two light emitting diodes 17 18 on the rear side for the status display not available on some devices The state LED 17 is the lower one the communication LED 18 is above Display Meaning State L...

Page 7: ...ning the resources are ordered in the ProfiLux in the following manner The numbering starts in every case with the internal resources of the ProfiLux followed by the resources of the module cards inst...

Page 8: ...2 Conductivity S 2 and Redox 2 are the internal sensor inputs of the first found by ProfiLux Expansion Box Airtemperature 1 and Humidity 1 originate from the PLM Humidity Temp in this Expansion Box L...

Page 9: ...ards in the slots of the Expansion Box Thereafter the interfaces of the second Expansion Box follow and so on Example In case of a ProfiLux 3 with a PLM 4L card and an Expansion Box with a PLM 4L the...

Page 10: ...ssigning the devices Only if all sensors and interfaces are checked and correctly assigned again the disabled devices can return to in operation again 3 6 The switching outputs of the Expansion Box Th...

Page 11: ...here the PLM 2L4S at the Expansion Box Here only the switching outputs from S1 to S16 are available the others are free Attention During assigning devices it is also possible here that the numbering...

Page 12: ...the module If you do not like to do the installation by yourself we can do this for you for a low charge possibly together with a firmware update Hint In the last slot Modul 4 only analog measurement...

Page 13: ...nsert the module The new module can be inserted into any slot except slot Modul 4 slot nearest to the housing This slot only supports analog measurement cards at the moment When you insert it pay atte...

Page 14: ...ection We assume no liability for direct damages indirect damages consequential damages and third party damages as far as it is legally permitted We do not take over guarantee that our product package...

Page 15: ...voltage 12 VDC Power consumption 200 mA pH measurement BNC input for pH sensors accuracy 0 1 pH measurement range 3 0 pH to 10 5 pH Temperature measurement Mini DIN socket for delivered temperature s...

Page 16: ...Bedienungsanleitung As of 04 20 2010 Seite 16 16...

Reviews: