TABLE OF CONTENTS
1) Machine range and identification
page
3-4
2) Safety instructions
fig.
1
page
5
3) Control panel
fig.
2
page
5
4) Handle
fig.
3
page
6
5) Rear part
fig.
4
page
6
6) Inferior rear part
fig.
5
page
7
7) Lower part
fig.
6
page
7
8) Brush unit
fig.
7
page
8
9) Squeegee unit
fig.
8
page
8
10) Machine commissioning
page
9-10
11)
12) Brushes
page
9
13) Tanks
page
10
14) Squeegee
page
10
15) Water filter
page
10
16) Problems - causes – solutions
page
11
17) Dimensions – Weights
page
12
18) Information regarding the machine and your dealer
page
13
2
PROBLEM
CAUSE
SOLUTION
The vacuum fan
does not start
•
Fan switch not enabled or
damaged.
•
Enable or replace the switch.
•
Water filter clogged
•
Clean the filter .
•
Water pipes clogged
•
Clean the solution feeding
pipes.
•
Tank empty
•
Fill the tank.
Solution flow
reduced or
absent
•
Solenoid valve blocked or
wires disconnected
•
Connect the wires, clean or
replace the solenoid valve.
•
Vacuum fan off.
•
Start the fan.
•
Squeegee not adjusted.
•
Adjust the squeegee
inclination.
•
Squeegee blades worn out or
damaged.
•
Replace the blades.
•
Vacuum fan filter clogged.
•
Clean the drilled disc of the
recovery tank
•
Vacuum pipe not connected or
damaged.
•
Connect or replace the pipe.
Water is not
collected
•
Vacuum pipe or squeegee
clogged.
•
Clean the pipe and the
squeegee.
•
Unsuitable brush or detergent.
•
Use different brushes or
detergent.
•
Brush worn-out.
•
Replace brush.
•
Solution tank empty .
•
Fill the solution tank.
•
Solution tap closed or not
sufficiently opened.
•
Open the tap more.
Poor quality
floor cleaning
•
Insufficient water flow .
•
Refer to chapter “solution flow
reduced or absent”.
11