TYPE OF USE
These devices were designed to vacuum liq-
uids or solids or both, according to the tech-
nical data table from the introduction to this
manual. They were designed only for this
use.
DANGER:
The manufacturer can not be held respon-
sible for any damage due to improper or
incorrect use.
Any other use releases the manufacturer
from liability for harm to persons and/or
property and invalidates any warranty
condition.
IMPROPER USE
Do not use the appliance to:
- Aspirate flammable, explosive, corrosive
and toxic substances.
- Aspirate hot substances.
- Do not use the appliance in liquid suction
mode to suction powder and vice versa.
Do not use the appliance in areas at risk of
explosion.
PREPARING
THE APPLIANCE
- Release the levers (1 Fig. 1) and remove
the cover (2 Fig. 2) complete with the mo-
tor unit.
- Check if inside the tank is the filter bag
(3 Fig. 3) from TNT (polyester); if not pre-
sent, insert it in the appropriate space.
- Place the cover back on (1 Fig. 1) and
lock it using the levers.
- Insert, as far as possible, the sleeve (4
Fig. 4) of the suction hose into the nozzle
(5 Fig. 4) on the drum.
- To release the sleeve (4 Fig. 4) press and
hold the button (6 Fig. 4) and then pull out
the sleeve (4 Fig. 4).
- Combine the flexible tube (7 Fig.5) with
the desired accessory (dust brush (8 Fig.
5), crevice nozzle (9 Fig. 5)).
NOTE:
The filter bag (3 Fig. 3) TNT (polyester) may
remain mounted while using the device as
a cleaner for liquids, after careful cleaning
(blowing) the dust accumulated while using
the vacuum cleaner device.
NOTE:
If you use the vacuum again as a dust vacu-
um, after cleaning liquids, make sure that the
inside of the tank and the filter bag Al (3 Fig.
3) are perfectly dried.
USING THE APPLICANCE
- The device is equipped with wheels and
can be pushed with handles.
- To lift it up insert your fingers under the
dedicated handle (10 Fig. 6) on the top of
the cover of the single version motor or
lift with the help of two people using the
handles (11 Fig. 7).
Starting up the appliance
- Insert the plug (12 Fig. 8) into the socket.
Single motor
- Press the switch (13 Fig. 9) to position “I”
to start the vacuum engine; lights, if lo-
cated on the switch will turn on.
Double motor
- Depending on the power required it is
possible to start only one motor by press-
ing the switch (13 Fig. 9) on “I” or both
switches (13, 14 Fig. 9) if a greater suc-
tion force is required.
Lights, if located on the switch will turn
on.
NOTE:
When the recovery tank is full, the noise
intensity increases and the device can no
longer aspire. Then you must switch off the
device and empty the tank as described in
the relevant paragraphs.
Manuale HD LINE_8050828_1ed_04-2017.indd 1
18/04/17 15:53
Summary of Contents for AD60 IK D HD
Page 4: ...www ghibliwirbel com Professional Cleaning Machines Since 1968 4...
Page 5: ...www ghibliwirbel com Professional Cleaning Machines Since 1968 5 0 I 0 I 0 I...
Page 8: ......
Page 13: ......
Page 14: ......
Page 15: ......