31 

 

L

YING SURFACE

,

 DIVIDED INTO

:

 

 

 

a.

 

Electrically adjustable backrest 

 

s. chapter 10.9 B

ACKREST

 and chapter 11.1.2 resp. chapter 

11.2.2 A

DJUSTMENT OF THE BACKREST

 

b.

 

Knee bend (inclination of the seat section) 

 

The 

INCLINATION

 of the seat section is adjustable by the 

electrically adjustable 

KNEE BEND

 

s. chapter 11.1.3 resp. chapter

 

11.2.3

 

A

DJUSTMENT OF THE 

INCLINATION OF THE SEAT SECTION

 

c.

 

Legrest 

 

The legrest 

is not

 adjustable. 

A

DJUSTABLE 

F

EET

 

s. chapter 6. A

SSEMBLY AND TRANSPORT OF THE 

MLR

 

S

ELECT

 

 

10.5 Gas springs 

 

 

The armrests as well as the headrest can be adjusted pneumatically using a gas 

spring using a lever. 

 

 

If you carry out any setting using the lever of the gas spring, you 

only

 need to 

operate the lever 

when lowering

 the armrests or headrest. 

 

 

Carry out a pulling movement upwards (

without operation of the respective 

leve

r) 

to lift

 an armrest and / or the headrest again. 

 
 

 

 

 
 

 

 

 
 

 

 

Summary of Contents for MLR SELECT V2

Page 1: ...ary depending on model Gharieni Group GmbH Gutenbergstraße 40 47443 Moers Germany Phone 49 0 2841 88300 0 Fax 49 0 2841 88300 999 Sales department 49 0 2841 88300 300 E mail service gharieni com Web www gharieni com Area to note the SERIAL NUMBER The serial number of the MLR SELECT is on the rating plate s chapter 7 RATING PLATE ...

Page 2: ...ructions carefully and operate the MLR SELECT exclusively in accordance with the intended use as described in the instruction manual This is the only way to protect your customers and yourself from dangers resulting from improper use Always keep the instruction manual within easy reach near the MLR SELECT THIS INSTRUCTION MANUAL MUST ALWAYS BE ACCESSIBLE TO EVERY PERSON WHO OPERATES THE MLR SELECT...

Page 3: ...rt 14 6 2 1 Use of the carrying aids 15 7 Rating plate 18 8 QR Code 19 9 Upholstery and design of the MLR SELECT 24 9 1 Upholstery 24 9 2 Versions of the base 25 10 Operation of the MLR SELECT 27 10 1 Characteristics 27 10 2 Model variants Number of actuators 28 10 2 1 MLR SELECT 4 actuators 29 10 3 Before first use 29 10 4 View example MLR SELECT ALU 30 10 5 Gas springs 31 10 6 Headrest 32 10 6 1...

Page 4: ...urg function 50 11 2 5 Locking function lock button of the hand control without memory function 51 12 Foot control optional equipment 52 12 1 Foot control with Bluetooth optional equipment 56 13 Heating system optional equipment 59 13 1 Operation 61 14 Vibro Wellness 10 optional equipment 64 14 1 Hand control 65 14 2 Operation 66 15 Reset 69 16 Cleaning and maintenance of the MLR SELECT 71 16 1 Cl...

Page 5: ...ol free 84 19 2 Skai cleaner 86 20 Conditions of transport storage and operation 87 20 1 Transport 87 20 2 Ambient conditions for storage and transport 87 20 3 Ambient conditions for operation 87 21 Technical Data 88 22 Disposal 90 23 Warranty 91 23 1 Exclusions from warranty 91 24 EC Declaration of Conformity 92 25 Status of Edition 92 Do not dispose of the MLR SELECT together with your domestic ...

Page 6: ... IT HAS BEEN READ AND UNDERSTOOD PRIOR TO USING THE SPA TABLE This instruction manual is an integral part of the product and must be carefully kept in a safe place to consult it throughout the equipment service life Copies of this instruction manual are available upon request The Gharieni Group GmbH shall not be held responsible for any damages direct or indirect caused to people animals or object...

Page 7: ...k of electrocution 1 Non compliance with the orders of this instruction manual endangers the operator s and customer s health and life and or can damage the spa table 2 All electrical work to connect the MLR SELECT to the mains must be carried out by a qualified professional Do not modify the energy supply The connection must be carried out in accordance with the current local and legal regulation...

Page 8: ...ECT from the mains before cleaning and or maintenance RISK OF ELECTRIC SHOCK 12 Never pull the power supply cable to unplug the MLR SELECT Always use the power plug itself to unplug the MLR SELECT RISK OF ELECTRIC SHOCK 13 Never touch the power plug the power switch or other electrical components with wet or damp hands RISK OF ELECTRIC SHOCK 14 Do not place or store the MLR SELECT close to a sourc...

Page 9: ...s the MLR SELECT or its housing RISK OF ELECTRIC SHOCK 11 The cables of the models incl the heating system and or the Vibro Wellness 10 function1 are between the upholstery and the underframe The upholstery may only be removed by persons authorized by Gharieni Group GmbH 12 For MLR SELECT with soft upholstery only for long periods of use of the heating system optional equipment always keep some fr...

Page 10: ...LECT outdoors 24 Do not allow any unauthorized person to operate the MLR SELECT 25 Use the MLR SELECT only on a level surface 26 Do not place any objects or liquids on the MLR SELECT The Spa Table as well as the material can be damaged thereby RISK OF ELECTRIC SHOCK RISK OF DAMAGE 27 Any repairs and maintenance work must be carried out by qualified professionals authorized by the Gharieni Group Gm...

Page 11: ... compliance with this instruction can seriously damage the adjustable feet of the MLR SELECT RISK OF DAMAGE 2 For safety reasons the MLR SELECT moves only while pressing a button of the hand control of the optional foot control with Bluetooth or one or more pedals of the optional foot control When you stop pressing all moving operation will stop immediately 3 Never rest stand or kneel on any part ...

Page 12: ...ble You can use it for e g cosmetic applications or full body massages in dry rooms etc Any other use is not permitted and will affect the warranty claims The MLR SELECT is intended for use in closed rooms with defined ambient conditions See chapter 20 CONDITIONS OF TRANSPORT STORAGE AND OPERATION No liability for personal injury or material damage will be accepted if these instructions are not fo...

Page 13: ...sure that there is enough space for the MLR Select so that it does not bump into anything even when fully extended 5 Delivery and unpacking of the MLR SELECT 5 1 Delivery The MLR SELECT is delivered and packed in a cardboard on a special pallet s fig below The MLR SELECT is in complete horizontal position and the upholstery is installed DELIVERY BY THE GHARIENI GROUP GMBH If the MLR SELECT is deli...

Page 14: ...packaging material and the special pallet on your own responsibility 5 2 Unpacking WARNING While unpacking the packaging should be kept away from children and pets RISK OF INJURY CHOKING HAZARD The MLR SELECT is delivered and packed in a cardboard on a special pallet s fig below A PACKAGING TAPES B UPPER CARDBOARD C SPECIAL PALLET D SHORT SIDES OF THE CARDBOARD 1 Cut the packaging tapes A with sci...

Page 15: ...ired positions electrically in a very short period and then focus entirely on your customer Before setting up make sure that there is enough space for the MLR Select so that it does not bump into anything even when fully extended WARNING The cables of the models incl the heating system and or the Vibro Wellness 10 function are between the upholstery and the underframe The upholstery may only be re...

Page 16: ...power cord must not be under the Spa Table otherwise the adjustable feet may squeeze the power cord and cause permanent damage while putting down the MLR SELECT RISK OF ELECTRIC SHOCK NOTICE The special pallet the MLR SELECT is delivered on has recesses s fig below Upon delivery the adjustable feet of the MLR SELECT stand in the respective recesses to prevent the Spa Table from inadvertent movemen...

Page 17: ...ND CONTROL WITH MEMORY resp chapter 11 2 HAND CONTROL WITHOUT MEMORY 2 You must set the backrest in upright position before you use the carrying aids To do this press the corresponding push button of the hand control button T 2 s fig in chapter 11 1 s fig in chapter 11 1 HAND CONTROL WITH MEMORY resp chapter 11 2 HAND CONTROL WITHOUT MEMORY 3 Then unplug the MLR SELECT 4 Insert the 4 carrying aids...

Page 18: ...r carrying aids only otherwise you can damage the MLR SELECT irreparably 8 Store the carrying aids in a safe place If the MLR SELECT must be carried or transported at a later point of time e g when moving it is only possible when using the four carrying aids 9 If the floor is not level you must ensure proper stability of the MLR SELECT by adjusting the four adjustable feet D s fig below After you ...

Page 19: ...ll expire the guarantee If you wish to contact the Gharieni customer service regarding your Spa Table we recommend taking a photo of the rating plate previously e g using a mobile phone or a digital camera This makes it easier for you to identify the information of the rating plate e g the serial number of the Spa Table to provide the required information to the customer service On the cover page ...

Page 20: ...r device and attach it To do this tap on the Select file button A window with options will then open The appearance of this window may differ from the illustration depending on your device and operating system After you have confirmed that you have read our data protection guidelines by marking the box at the end of the form the form with all the entries you have made is immediately sent to our cu...

Page 21: ...20 B QR CODE Figure similar position might differ ...

Page 22: ...21 Figure shows form that opens in the Internet browser of the device after the QR code is scanned ...

Page 23: ...22 Figure shows form that opens in the Internet browser of the device after the QR code is scanned ...

Page 24: ...23 Figure similar option window for adding a file Appearance may vary depending on the device and operating system ...

Page 25: ... available in various colours PU is more elastic and provides perfect and soft lying comfort Furthermore it is easy to clean It is oil proof waterproof and washable up to 90 C Fig similar colour and decor can vary depending on model SOFT UPHOLSTERY MADE OF POLYURETHANE PU The MLR SELECT can be equipped with an extra soft comfortable and high quality one piece upholstery without illustration The in...

Page 26: ...able with eight different versions of the base MLR SELECT WOOD The base of the MLR SELECT WOOD consists of a solid plate with elegant wooden decor s fig below MLR SELECT ALU The base of the MLR SELECT ALU consists of a solid aluminium plate s fig below ...

Page 27: ... maximum stability s fig below MLR SELECT VINTAGE The base of the MLR SELECT VINTAGE in an exclusive metal wood look offers extensive space for towels and everything else you need for your work s fig below MLR SELECT K8 The base of the MLR SELECT K8 is equipped with storage compartments and optionally with an integrated warming drawer s fig below ...

Page 28: ...ions or full body massages in dry rooms etc The MLR SELECT is available with eight different versions of the base MLR SELECT WOOD MLR SELECT ALU MLR SELECT STATIC MLR SELECT VINTAGE MLR SELECT K8 with or without warming drawer MLR SELECT ELLIPSE with or without storage space see also chapter 9 2 VERSIONS OF THE BASE The MLR SELECT is available in two upholstery variants s chapter 9 1 UPHOLSTERY Th...

Page 29: ...section is adjustable by the electrically adjustable knee bend The armrests can be adjusted pneumatically s chapter 10 7 ARMRESTS The headrest can be adjusted pneumatically s chapter 10 6 HEADREST The maximum lifting capacity of the MLR SELECT is approx 300 kg The maximum load capacity of the lying surface of the MLR SELECT is approx 350 kg The maximum load capacity of the armrests is 25 kg 10 2 M...

Page 30: ...ctuator 2 Electrical adjustment of the INCLINATION OF THE SEAT SECTION adjustable by the electrically adjustable KNEE BEND The LEGREST is not adjustable 10 3 Before first use Before first use please check that all components are present s chapter 3 SCOPE OF DELIVERY and that they are not visibly damaged Make sure that the socket for the spa table is properly grounded and has the correct mains volt...

Page 31: ... 11 1 1 resp chapter 11 2 1 ADJUSTMENT OF THE WORKING HEIGHT s chapter 11 1 4 resp chapter 11 2 4 ADJUSTMENT OF THE TRENDELENBURG ANTI TRENDELENBURG FUNCTION 3 ARMRESTS Pneumatically adjustable and swivelling s chapter 10 5 GAS SPRINGS and chapter 10 7 ARMRESTS 4 HEADREST Pneumatically adjustable Incl nose slot s chapter 10 5 GAS SPRINGS and chapter 10 6 HEADREST ...

Page 32: ...STMENT OF THE INCLINATION OF THE SEAT SECTION c Legrest The legrest is not adjustable 6 ADJUSTABLE FEET s chapter 6 ASSEMBLY AND TRANSPORT OF THE MLR SELECT 10 5 Gas springs The armrests as well as the headrest can be adjusted pneumatically using a gas spring using a lever If you carry out any setting using the lever of the gas spring you only need to operate the lever when lowering the armrests o...

Page 33: ...Select RISK OF TIPPING RISK OF DISINTEGRATION RISK OF INJURY The headrest is freely and manually adjustable s below fig 1 2 and 3 You can incline the headrest positive by 35 and negative by 48 using the lever which is on the underside of the headrest fig 1 Lock the set position by releasing the lever see also chapter 10 5 GAS SPRINGS FIG 1 FIG 2 FIG 3 Fig similar figures serve as an example only ...

Page 34: ...nally support the face of the person to be treated see also chapter 18 1 GEL CUSHION FOR NOSE SLOTS FIG 4 FIG 5 Fig similar figures serve as an example only 10 6 1 Headrest versions For the MLR Select the dual headrest is available as an option at extra cost This headrest has a round and a horn shaped face support see fig 6 The scope of delivery of the dual headrest includes an air cushion with ha...

Page 35: ... Armrests WARNING Do not carry out any physical force to the armrests regardless of the setting of the lying surface Non compliance can cause permanent damage to the construction of the MLR Select RISK OF TIPPING RISK OF DISINTEGRATION RISK OF INJURY You can lower and lift each armrest in the same way as the headrest manually gas spring see also chapter 10 5 GAS SPRINGS Additionally the armrests o...

Page 36: ...10 7 1 Additional locking of the armrests The armrests of the MLR SELECT can be locked additionally using the laterally mounted locking button s fig below The additional lock enables higher stability and safety of the armrests LOCKING OF THE ARMRESTS 1 Push the inner red button inward to lock the armrests 2 Now the armrests are locked UNLOCKING OF THE ARMRESTS 1 Pull the outer black button forward...

Page 37: ...e levers s chapter 10 7 ARMRESTS Otherwise the construction and the mechanics of the armrests can be damaged permanently RISK OF DAMAGE 10 8 Legrest The legrest is not adjustable 10 9 Backrest The backrest can be adjusted electrically s chapter 11 1 2 resp 11 2 2 ADJUSTMENT OF THE BACKREST ...

Page 38: ... and holding down the corresponding push button Furthermore you can individually adjust and save two memory positions Saving of certain lying positions is described in chapter 11 1 5 MEMORY FUNCTIONS OF THE HAND CONTROL Recalling the four preset positions is also possible The hand control has 12 buttons Adjustment of the working height the backrest the seat tilt and the Trendelenburg anti Trendele...

Page 39: ...I TRENDELENBURG FUNCTION T 5 PROGRAM BUTTON P1 PROGRAM BUTTON P1 moves the bed to the fixed entry position The fixed entry position cannot be changed T 6 PROGRAM BUTTON P2 PROGRAM BUTTON P2 moves the bed to the fixed S curved position The S curved position cannot be changed T 7 PROGRAM BUTTON P3 PROGRAM BUTTON P3 moves the bed to the fixed pedicure position The pedicure position cannot be changed ...

Page 40: ...he first individually adjusted and saved position T 10 MEMORY BUTTON M2 MEMORY BUTTON M2 is used to save and recall the second individually adjusted and saved position T 11 LOCK BUTTON The LOCK BUTTON locks and unlocks the hand control the actuators T 12 BUTTON FOR THE HEATING SYSTEM optional By using this button you can switch on the heating system set it in 3 levels and switch it off again ...

Page 41: ...e hand control Press the button once and hold it down to raise the MLR SELECT Press the button twice and hold it down to lower the MLR SELECT The horizontal WORKING HEIGHT of the MLR SELECT STATIC WOOD VINTAGE K8 and ELLIPSE is adjustable from approx 61 cm up to approx 91 cm if the adjustable feet are retracted The horizontal WORKING HEIGHT of the MLR SELECT ALU is adjustable from approx 63 cm up ...

Page 42: ...t section in horizontal position 11 1 2 Adjustment of the backrest The inclination of the backrest can also be adjusted using the hand control For adjustment of the backrest press the corresponding button T 2 s fig in chapter 11 1 HAND CONTROL WITH MEMORY FUNCTION For the direction of movement please note the arrow symbols and the number of dots above them on the hand control Press the button once...

Page 43: ...f the lying surface press the corresponding button T 4 s fig in chapter 11 1 HAND CONTROL WITH MEMORY FUNCTION For the direction of movement please note the arrow symbols and the number of dots above them on the hand control The MLR SELECT can be inclined to the desired direction of movement up to an inclination angle of approx 14 If an insufficient height is reached during the adjustment of the i...

Page 44: ...ION The memory positions are saved in the same way as the electrical settings of the MLR SELECT using the double tap system SAVING THE MEMORY POSITIONS 1 Set the desired position as usual with the buttons T 1 to T 4 2 Press button M 1 or M 2 twice double tap system and keep it pressed for about 3 seconds 3 An acoustic signal sounds when the setting has been successfully saved 4 The respective memo...

Page 45: ...ime is given as follows via flashing of all LEDs of the hand control ana several beeps depending on the automatic locking time automatic locking after 30 minutes 1 beep and 1 time flashing of all LEDs of the hand control automatic locking after 60 minutes 2 beeps and 2 times flashing of all LEDs of the hand control automatic locking after 90 minutes 3 beeps and 3 times flashing of all LEDs of the ...

Page 46: ...n through flashing of all LEDs of the hand control and beeps The automatic locking time is always changed in this sequence 30 min 60 min 90 min 120 min no automatic locking Buttons T 9 T 10 F3 LOCKING THE DRIVES MANUALLY 1 To lock the drives manually press the LOCK button T 11 of the hand control and keep it pressed for about 2 seconds 2 Successful locking is confirmed by an acoustic signal and th...

Page 47: ...trol without memory function You can control the two lifting columns and the actuators by pressing and holding down the corresponding push button The hand control has 6 buttons Adjustment of the working height the backrest the seat tilt and the Trendelenburg anti Trendelenburg function buttons T 1 T 4 is done by a double tap system This is for safety reasons A movement that is associated with dang...

Page 48: ...NATION seat area T 4 Button for adjustment of the TRENDELENBURG ANTI TRENDELENBURG FUNCTION T 5 LOCK BUTTON The LOCK BUTTON locks and unlocks the hand control the actuators T 6 BUTTON FOR THE HEATING SYSTEM optional By using this button you can switch on the heating system set it in 3 levels and switch it off again 1 SYMBOLS FOR THE DOUBLE TAP SYSTEM The working height backrest inclination of the ...

Page 49: ...f the MLR SELECT STATIC WOOD VINTAGE K8 and ELLIPSE soft upholstery is adjustable from approx 66 cm up to approx 96 cm due to the thicker upholstery if the adjustable feet are retracted The horizontal WORKING HEIGHT of the MLR SELECT ALU soft upholstery is adjustable from approx 68 cm up to approx 98 cm due to the thicker upholstery if the adjustable feet are retracted Extracting of the adjustable...

Page 50: ...that no body parts or items are between the parts of the MLR SELECT while adjusting the treatment position RISK OF CRUSHING 11 2 3 Adjustment of the inclination of the seat section Via the electrically adjustable knee bend the inclination of the seat section thigh section to knee bend section can also be adjusted easily using the hand control For the adjustment of the inclination of the seat secti...

Page 51: ...p to an inclination angle of approx 14 If an insufficient height is reached during the adjustment of the inclination the MLR SELECT moves up automatically to avoid collision with the base During the crossover from Trendelenburg to Anti Trendelenburg the MLR SELECT stops for approx one second when reaching the horizontal position If you continue to press the corresponding button the MLR SELECT will...

Page 52: ...ystem ACTIVATING THE LOCKING FUNCTION 1 To activate the locking function press the LOCK button T 11 of the hand control and keep it pressed for about 3 seconds 2 Successful locking is confirmed by an acoustic signal and the LED above the button on the hand control also lights up 3 The actuators are now locked DE ACTIVATING THE LOCKING FUNCTION 1 To unlock press the LOCK button T 11 on hand control...

Page 53: ...e activation of the locking function and operation of the heating system is done in combination with several pedals of the foot control As with the hand control operation is in double tap system This is for safety reasons A movement that is associated with danger is made consciously by this For the direction of movement please note the arrow symbols and the number of dots on the stickers of the le...

Page 54: ... CONTROL LEFT PART FOOT CONTROL RIGHT PART FOOT CONTROL LEFT PART 1 WORKING HEIGHT UP DOWN 2 BACKREST UP DOWN FOOT CONTROL RIGHT PART 3 INCLINATION seat area UP DOWN 4 TRENDELENBURG ANTI TRENDELENBURG FUNCTION ...

Page 55: ...them pressed until the position is reached THE ENTRY POSITION CANNOT BE CHANGED Lock unlock Left part of the foot control press pedal 1 and right part of the foot control press pedal 4 and keep them pressed until the bed is locked For confirmation an acoustic signal sounds and the LED diode in the middle part of the foot control lights up To unlock the bed press the two pedals on the foot control ...

Page 56: ... for adjustment of the Trendelenburg anti Trendelenburg function pedal 2 3 and 4 Storing the two individual memory positions M 1 or M 2 also works in the same way as using the hand control using double tap press the pedal twice and hold to store press once and hold to recall the position Locking unlocking also works exactly as with the hand control using double tap When the operation of the bed is...

Page 57: ...ously by this By simply pressing a button and keeping it pressed a movement is made upwards Pressing a button twice double tap system and keeping it pressed makes a movement in the opposite direction Some functions are also set by double tapping When purchasing a MLR SELECT the hand control is included as standard Optionally for an additional charge the foot control with Bluetooth can be purchased...

Page 58: ...l or to switch off the heating system the buttons of the Bluetooth foot control must be held down for approx one second LEFT PART OF THE FOOT CONTROL 1 WORKING HEIGHT UP DOWN 2 BACKREST UP DOWN RIGHT PART OF THE FOOT CONTROL 3 INCLINATION OF THE SEAT AREA UP DOWN 4 TRENDELENBURG ANTI TRENDELENBURG FUNCTION ...

Page 59: ...CHANGED P4 Massage position Press the left part of the foot control button 2 and the right part of the foot control button 4 simultaneously twice double tap and keep them pressed until the position is reached THE MASSAGE POSITION CANNOT BE CHANGED Unlock To unlock the bed press both buttons 1 left part of the foot control and 4 right part of the foot control twice in quick succession double tap an...

Page 60: ...ON Various automatic locking times can be set s chapter 11 1 6 LOCKING FUNCTION OF THE HAND CONTROL WITH MEMORY FUNCTION The heating cycle currently running is not affected by this Even a manual locking does not affect the currently running heating cycle and has no effect on the operation of the heating system s chapter 11 1 6 LOCKING FUNCTION OF THE HAND CONTROL WITH MEMORY FUNCTION and chapter 1...

Page 61: ...SELECT from the mains if it is not used for a longer time e g during the night WARNING People with acute pain venous disorders low blood pressure inflammatory processes and other medical conditions that make heat applications or this form of client positioning questionable must always consult a doctor before use WARNING Never use the MLR SELECT on people who are under the influence of alcohol or d...

Page 62: ...N Use this button to switch on the heating system The heating system comes with three heat power levels To quickly heat up the bed s surface before starting treatment we recommend setting the heating system to level 2 only in exceptional cases to level 3 highest level Please refer to the following charts to find information on how to operate the heating system After a total time of 90 minutes the ...

Page 63: ...sh this button again level 2 double impulse lights up for 0 3 seconds interval 1 second 60 button Push this button again level 3 triple impulse lights up for 0 3 seconds interval 1 second 90 button Push this button again Power off NOTICE If the heating system is not present on your bed this will be indicated by the LED above the button flashing rapidly when you press the button for operating the h...

Page 64: ...buttons 2 4 Push these pedals buttons again Power off NOTICE For operation of the heating system using the foot control or the Bluetooth foot control s chapter 12 and 12 1 NOTICE If the heating system is not present on your bed this will be indicated by the rapid flashing of the LED in the middle part of the optional foot control with cable when you press the pedals to operate the heating system N...

Page 65: ...thrombosis suffers from pain due to unknown reasons 2 Apply to healthy people only WARNING Do not open the housing of the hand control Non compliance will expire the warranty WARNING Liquids must not get into the hand control RISK OF ELECTRIC SHOCK WARNING Persons with a pacemaker must not operate or use the massage unit as the pacemaker can be negatively influenced WARNING The cables of the model...

Page 66: ...nd control s fig 9 below to activate the individual sections in pairs fig similar fig serves as an example only FIG 8 FIG 9 1 ON OFF BUTTON 2 INDIVIDUAL BUTTON 3 PULSE MASSAGE BUTTON PULSE BUTTON 4 WELLNESS MASSAGE BUTTON WAVE BUTTON 5 INTENSITY BUTTONS SHOULDER AREA BACK AREA 6 INTENSITY BUTTONS FUSELAGE AREA BACK AREA 7 INTENSITY BUTTONS PELVIC AREA BACK AREA ...

Page 67: ...ting intensity level 2 medium intensity When the massage unit has been operated before the previously set programme is started again INDIVIDUAL PULSE OR WELLNESS MASSAGE INDIVIDUAL BUTTON 2 When the massage unit is operated for the first time the manufacturer s setting is activated intensity level 2 medium intensity When an individual setting has been set before s below INDIVIDUAL SETTING the prev...

Page 68: ...hen the lowest intensity level 1 has been reached press one of the INTENSITY BUTTONS 5 9 again to switch off the relevant motor When you switch off all massage motors the massage is stopped You can change from the manufacturer s setting intensity level 2 medium intensity to your individual setting by pressing the INDIVIDUAL BUTTON 2 The individual settings are saved after the massage PULSE MASSAGE...

Page 69: ...you press the WAVE BUTTON 4 a fourth time the first programme will be started again You can select three levels of speed with the and BUTTONS 10 You can select three levels of intensity with the INTENSITY BUTTONS 5 9 Please note The WELLNESS MASSAGE will be restarted in the manufacturer s setting HOW TO FINISH A MASSAGE A timer finishes a massage after 15 minutes automatically If you want to stop ...

Page 70: ...with memory function resp without memory function 2 The actuator for the inclination of the seat area must be level with the leg section calf area i e set horizontally ATTENTION Please keep button T 3 of the respective hand control pressed until the actuator switches off Reset 2 lifting columns Press the upper two buttons of the respective hand control s fig below simultaneously and hold them down...

Page 71: ...ssed for 2 3 seconds longer after reaching the end position WARNING The adjustment initialization must be carried out manually i e each drive must be run individually Do not use any of the memory buttons for this WARNING Ensure that there are no persons body parts of persons animals or objects between the lying surface and the base RISK OF COLLISION RISK OF CRUSHING RISK OF INJURY RISK OF DAMAGE ...

Page 72: ...ble the upholstery and or of the material of the base caused using unsuitable cleaning agents is not covered by the guarantee or warranty Do not wear any arm and finger decoration such as rings or bracelets while carrying out any cleaning or maintenance operations Otherwise you can scratch and damage the upholstery and or the material of the base of the MLR SELECT unintentionally Use water or a mi...

Page 73: ... of a detergent suitable for this material also available from Gharieni see chapter 19 UPHOLSTERY CARE AND CLEANING AGENTS NOTICE The upholstery of the MLR SELECT can also be made of artificial leather or Ferrari Stamskin Top artificial leather This material can be cleaned with a cloth with some detergent which must be suitable for artificial leather 16 2 Cleaning the housing and the fittings Clea...

Page 74: ...GHARIENI GROUP GMBH Standard cosmetic applications e g facials etc 5 piece terry cover The 5 piece terry covers are available with or without oil repellent PU coating Massages including a small amount of oil These treatments require a protective cover made of PU as the second outer skin of the MLR SELECT so to speak It protects the upholstery from stains of oil and seeping in of oil Detailed expla...

Page 75: ... be replaced please contact the customer service SINGLE MOTOR DOES NOT WORK 1 Actuator plug is not connected properly 1 Connect plug properly 2 Hand control is defective 2 Hand control must be replaced please contact the customer service 3 Control box is defective 3 Control box must be replaced please contact the customer service 4 Actuator plug or plug is defective 4 Cord plug must be replaced pl...

Page 76: ...ted from the mains for daily use 7 Check the power cord regularly for signs of damage 8 If the mains cable is damaged it may only be replaced by Gharieni Group GmbH or a customer service authorized by Gharieni Group GmbH or a qualified specialist electrical engineer DANGER In case of defects or malfunctions of the spa table contact customer service immediately Use of the spa table must be disconti...

Page 77: ...to help 18 1 Headrests 18 1 1 Dual headrest This newly designed headrest offers full flexibility for every requirement This headrest has a round or a horn shaped face cushion The scope of delivery of the dual headrest includes an air cushion including a hand pump which allows individual adjustment of the height of the respective face cushion s figs below fig 1 fig 2 fig 3 ...

Page 78: ... fluid see also chapter 10 6 HEADREST GEL CUSHIONS FOR NOSE SLOTS ARTICLE NUMBER 45010 For detailed information regarding the right size and suitable version for your Spa Table please contact our sales department Our team is happy to help 18 3 Towels for nose slots disposable cloths DISPOSABLE CLOTHS s fig below for the nose slot of the headrest of the MLR SELECT are optional available for an addi...

Page 79: ...ional charge During treatment this neckrest supports the cervical spine effectively The NECKREST DENTALAX is available in white or in colour The lying comfort will be increased significantly when using the NECKREST DENTALAX SMALL PART GREAT EFFECT Fig similar colour and workmanship may vary depending on the model selected For detailed information regarding the right size and suitable version for t...

Page 80: ...ll perfectly protect your working equipment from dirt and heavy use Machine laundry max 60 C for hygienic cleaning is possible due to the high quality material Internal elastic bands keep the single sections exactly in the right position All functions of the Spa Tables will continue working Our COVERS are available in three different colours white choco and crème You can order the relevant cover w...

Page 81: ...lient water and oil repellent and washable up to 90 0 C Fig similar fig serves as an example only For detailed information regarding the right size and suitable version of the covers as well as the compatibility with your Spa Table please contact our sales department Our team is happy to help 18 5 3 Protective foot cover A PROTECTIVE FOOT COVER s fig below for your Spa Table is optional available ...

Page 82: ...ok and loop fastener on the Spa Table on your own responsibility If you would like to order a protective foot cover for your Spa Table at a later point of time please indicate during the ordering process that the fleece strip Counter Velcro should be supplied 18 6 Holder for magnifying lamps An extendable holder for magnifying lamps made of stainless steel is available as an option for the MLR SEL...

Page 83: ...mes a scentful experience Press buttons P3 and P4 F 2 on the hand control simultaneously to switch the fragrance generator on or off see illustration below If the fragrance generator is switched on the diodes above the buttons on the hand control light up and the diode on the fragrance generator also lights up The fragrance generator is located on the underside of the lying surface in the chest ar...

Page 84: ... 6 TYPES Á 15 ML IN A PLASTIC BAG ITEM NUMBER 36008 The fragrances are also available individually in the 150 g tin NOTICE During adjustment of the bed the fragrance generator is switched off for a short time After the bed has been adjusted it is switched on again ...

Page 85: ...are and cleaning of the upholstery mikrozid sensitive removes bacteria fungi and viruses e g HBV Rota Vaccinia etc mikrozid sensitive is available as liquid Suitable for cleaning of PU and artificial leather upholstery Without alcohol Please follow the manufacturer s application instructions on the bottle MIKROZID SENSITIVE LIQUID ITEM NUMBER 79417 ...

Page 86: ...85 For more information visit the manufacturer s website at the following link https www schuelke com intl en products mikrozid sensitive liquid php ...

Page 87: ... thorough care and cleaning of the artificial leather upholstery we additionally recommend Skai cleaner Skai cleaner is available in a 200 ml spray bottle Especially suitable for cleaning artificial leather SKAI CLEANER ITEM NUMBER 79427 ...

Page 88: ...ELECT you will need the help of several persons Always consider the dimensions of the MLR SELECT Narrow hallways doors or staircases can make the transport difficult or impossible 20 2 Ambient conditions for storage and transport TEMPERATURE from 10 C to 50 C ambient temperature ATMOSPHERIC PRESSURE from 700 to 1060 hPa RELATIVE HUMIDITY from 20 to 90 at 30 C non condensing 20 3 Ambient conditions...

Page 89: ... 91 cm Adjustable height MLR SELECT Alu approx 63 cm 93 cm Adjustable height MLR SELECT Static Wood Vintage K8 Ellipse soft upholstery approx 66 cm 96 cm Adjustable height MLR SELECT Alu soft upholstery approx 68 cm 98 cm Inclination of the headrest approx 35 48 Inclination of the backrest approx 0 70 Inclination of the Trendelenburg anti Trendelenburg function approx 14 Lifting capacity 300 kg ma...

Page 90: ...tric shock type B Protection class against penetration of substances IP X6 Technical modifications reserved HEATING SYSTEM GENERAL TECHNICAL DATA Power supply 100 240 V 50 60 Hz Power consumption Output approx 120 W Technical modifications reserved VIBRO WELLNESS 10 GENERAL TECHNICAL DATA Power of transformer primary 230 V AC 50 Hz 120 mA max Power of transformer secondary 13 5 V AC 1 A 13 5 VA Pr...

Page 91: ...power cord Dispose of the power cord and the plug immediately 6 The MLR SELECT is made of metal and plastic components electronic components electric cables Dispose of the separate components in accordance with the current local disposal regulations 7 Dispose of any paper and cardboard into the corresponding containers 8 Dispose of any plastics into the corresponding containers 9 If suitable conta...

Page 92: ...inds of lamps as well as glass panels consumables such as terry towels etc Furthermore no warranty claims will be granted if the spa table and its associated components have been damaged due to improper use damage to the spa table and its associated components has been caused by gross negligence the malfunction occurs through the fault of the operator stickers such as rating plate warning notices ...

Page 93: ...MLX Limber PediSpa series MLR Wet MLW Space MLX iDome MLX i3 MLR MLX RLL series Ellipse 601 E Line 601 Podo 2022 Relevant EU directives and harmonized standards used 2006 42 EU Machinery Directive 2014 35 EU Low Voltage Directive 2014 30 EU Electromagnetic Compatibility Directive 2011 65 EU RoHS Directive DIN EN ISO 12100 2011 Safety of machinery general principles for design Risk assessment and r...

Page 94: ... NOTES THE OWNERSHIP RIGHTS TO THIS INSTRUCTION MANUAL ARE RESERVED REPRODUCTION OR TRANSFER TO THIRD PARTIES IS PROHIBITED WITHOUT THE CONSENT OF GHARIENI GROUP GMBH GHARIENI GROUP GMBH RESERVES THE RIGHT TO PROTECT ITS PROPERTY RIGHTS AND TO PROSECUTE ANY MISUSE SALES AND SHOWROOM PRODUCTION PICK UP AND REPAIR Gharieni Group GmbH Gutenbergstraße 40 47443 Moers Germany Gharieni Group GmbH Am Schü...

Reviews: