background image

 

not equipped.

 (use 2.5mm

2

 cuprum wire to contact with    the    ground bolt) 

 

2.  Don’t  start  to  heat  when there  is  no  oil  in  frypot  or  the  oil  lever  lower  than  element,  otherwise  the 

elements will be burn. Please don’t wash the heating element by cool water until they are cooling, or it 

will explode 

 

3. Latch the lid before heating. Don’t operate the securing hook and draining the oil. Before you open 

the fryer lid, to make sure the there is no pressure in the frypot, that means the pressure gauge shows “0”. 

After 30 second, you can open the fryer lid to avoid explosion for the pressure. 

 

4. In order to keep the good sealing between fryer pot and fryer lid, do not use handle or some other hard 

tools to strike the fryer lid and mouth of fryer. 

 

5. The rubber seal of the fryer lid can not be dismantled of yourself. For it may effect the sealing. While 

it is not working, you should close the fryer lid, but not too tight to avoid the aging of the seals. 

 

6. You should cut off the power if the machine is not working in order to avoid explosion for the wrong 

operation. 

 

V. Maintenance and Upkeep of the Machine   

1.

 

Clean the overflow valve twice weekly, screw the screw lid, and clean the gravity block, making it 

jump freely and open and close flexibly. Check the general electricity and screws of power line, and 

joints monthly. If any loose, fasten them to make them contact well and control sensitively. 

 

2.

 

Clean the smear away from the electro thermal pipe in the boiler and cabinet after daily work is over 

to keep clean and sanitary and enhance the use life span of the machine.

 

 

 

3.

 

After a relatively long time use, the rubber gasket shall be replaced in time if it is found aging and 

ineffective.  Loosen  the  glue  bar  fastening  screws  of  four  sides  on  the  cover,  take  out  the  glue  bar 

from the groove slowly, put new sealing rings into the groove, and 

fasten the screws. 

4.

 

The machine is  equipped with  overheating protector. 

If the temperature controller is out of 

work  and  the  oil  temperature  is  up  to  250

,  temperature  limiter  can  cut  off  the  heating  power  to 

make  sure  of  the  safe.  Operator  should  check  the  reason  for  overheat  and  try  to  get  rid  of  it.  If 

needed, you should press the reset key in the “temperature limiter” to restart the machine. 

 

 
 
 
 
 

Summary of Contents for EHFDY491

Page 1: ...EHFDY491 Electric Pressure Fryer with pump Electric Pressure Fryer INSTRUCTION MANUAL Read this manual carefully prior to use Technology is subject to change without notice...

Page 2: ...d Voltage 3N380V 2 Rated Frequency 50Hz 3 Rated Input Power 13 5Kw 4 Rated Working Pressure 0 085MPa 5 Output 25kg h 6 Range of Temperature Control 50 200 adjustable the highest temperature you set ca...

Page 3: ...oil continuously to heat it fast and well proportioned 7 When its delivery the pressure of the automatic overflow valve is usually set at 0 07Mpa to 0 08MPa if the indication of the pressure gauge exc...

Page 4: ...ey now you can put the prepared food into the basket the machine is equipped with one basket using the handle of the basket to lift the basket to the fry pot then take the handle of the basket away an...

Page 5: ...be stand side face in case the hot air shall emit to scald his wrist The operator must have a good knowledge of how to operate the machine to ensure the security The workers are forbidden to leave the...

Page 6: ...o avoid explosion for the wrong operation V Maintenance and Upkeep of the Machine 1 Clean the overflow valve twice weekly screw the screw lid and clean the gravity block making it jump freely and open...

Page 7: ...ting well Adjust the wire s contact 5 Not timing Circle not contacting well Adjust the wire s contact Time Controller not work Reset the controller 6 Operating pressure too high Deadweight clogged Tur...

Reviews: