warning
Read the instructions before installation and use.
-This appliance must be installed and the gas cylinder stored in
accordance with the regulations in force;
-Do not obstruct the ventilation holes of the cylinder housing;
-Do not move the appliance when in operation;
-Shut off the valve at the gas cylinder or the regulator before moving
the appliance;
-The tubing or the flexible hose must be changed within the
prescribed intervals;
-Use only the type of gas and the type of cylinder specified by the
manufacturer;
The LP tank used with your patio heater must meet the following
requirements:
Purchase LP tanks only with these required measurements:
(31.8cm) (diameter) x 58 cm) (tall) with 15kg capacity maximum.
-In case of violent wind particular attention must be taken against
tilting of the appliance; Keep the appliance at least 1m from the gas
cylinder.
A regulator(compliees with EN16129:2013 and the national regulation)
of the correct pressure corresponding to the appliance category.
Use 30mbar regulator for butane/propane under the category I3B/P(30).
Use 30mbar regulator for butane under the category I3+(28-30/37).
Use 37mbar regulator for propane under the category I3+(28-30/37).
Use 50mbar regulator for butane/propane under the category I3B/P(50).
It's recommended to use flexible hose that approved by EN16436:2014.