INSTRUCTION & OPERATIONAL MANUAL
5.
Electrical Schematic Diagram:
6.
Troubleshooting
All above is just for reference. If there is any accident while your
cooking, stop using is right away and let the professional staff to deal
with it.
Accident
Reason
Trouble Shooting
1.Connect the
power, the indicator
light is not bright.
1. The power is not
well connected.
2. Fuse is blown
out.
1. Fasten the power
line.
2. Replace the fuse.
2. Yellow indicator
light does not
extinguish, and the
temperature is
continuously
increased.
1. The indicator
light is wrongly
connected.
2. Thermostat does
not work.
1.
Connect the light
correctly.
2.
Replace the
thermostat.
3. Yellow indicator
light is not bright,
and the temperature
is controlled well.
1. Indicator light is
not connected well.
2. Indicator light is
burned.
1. Fasten the
connecting line.
2. Replace the
indicator.