![GFA FG 40-31,75 Ex Installation Instructions Manual Download Page 6](http://html1.mh-extra.com/html/gfa/fg-40-31-75-ex/fg-40-31-75-ex_installation-instructions-manual_2219493006.webp)
6
Pos: 1 /BA_Module_Manuell/MAL_Fangvorrichtungen FG 40-120/06_Funktionsbeschreibung Montage Fangfall/06_Funktionsbeschreibung_Montage_Fangfall_ATEX_00000_M001 (2020-02-18 08:06:24) @ 13\mod_1389279129057_28.docx @ 826650 @ 11111 @ 1
4
Function
1
Hollow shaft
2
Safety switch/
Line
3
Plunger
4
Floating foot
5
Cover (aluminium)
F
max
Permissible bearing
(see technical data)
In normal operation, the safety brake functions similar to pedestal bearings. The safety brake
is tripped as soon as the maximum operating speed in DOWN direction is exceeded. This
results in the following reactions:
The shaft is blocked in DOWN direction (
➊
).
The safety switch is actuated to interrupt the control current (
➋
).
Release is optically indicated by a red plunger (
➌
).
Operating position:
Braking position: