Page 19
For functioning as a switching contact, impulse or continuous, the switching position must be
adjusted by limit switch S6.
Impulse signal
On reaching the limit switch the relay contact is made for 1 second.
Continuous signal
Relay contact is activated as long the limit switch is made.
Potential free changeover contact
X9
In
menu 2.5
this contact is able to work for several functions.
Important note!
It is only possible to work with one adjusted function.
Short circuit / overload monitor
The control TS 956 provides 230V AC for external devices.
230V AC; max. 1A
Maintenance cycle counter
Free adjustable maintenance cycle counter
Menu 8.5
makes it possible to pre-adjust a max.
No of cycles until a maintenance is agreed.
The no of cycles can be adjusted from 1.000 up to 99.000; the adjustment is possible in
steps of 1.000 cycles.
Different reactions can be chosen if the point of pre- adjusted maintenance cycles has been
reached, see
Menu 8.6
Whenever the final open limit has been contacted the pre-adjusted number will be reduced
with 1 until 0 is reached.
When maintenance was done the cycle counter could be re-adjusted to a new maintenance
period and count down starts again.
FUNCTION DESCRIPTION