Completion of initial operation / inspection / operation
Check the following components and after that, mount all covers.
Gearbox
Check drive unit for oil loss (some drops are not critical). Protect output shaft permanently
against corrosion.
Oil loss!
Oil loss may render explosion protection ineffective. Oil maintenance is
inadmissible.
Motor
Check motor for defective bearings
Mounting
Check all mounting elements (consoles, torque mounts, screws, retaining rings etc.) for
tightness and impeccable condition.
Electric wiring
Check connection cables and cables for damage or pinches. Check screw connections for
correct seating and electrical contact.
Emergency actuation
Function to be checked in a de-energised state. Check for correct functioning is to be carried
out between the final limit positions only.