+GF+ GF 3-2630-X Manual Download Page 2

2

GF 263X Series Chlorine Electrodes 

Dimensions

  Warranty Information

  Safety Information

Refer to your local Georg Fischer Sales office for the most 

current warranty statement.
All warranty and non-warranty repairs being returned must 

include a fully completed Service Form and goods must be 

returned to your local GF Sales office or distributor. 

 

Product returned without a Service Form may not be  

warranty replaced or repaired.
GF products with limited shelf-life (e.g. pH, ORP, chlorine 

electrodes, calibration solutions; e.g. pH buffers, turbidity 

standards or other solutions) are warranted out of box but not 

warranted against any damage, due to process or application 

failures (e.g. high temperature, chemical poisoning, dry-out) 

or mishandling (e.g. broken glass, damaged membrane, 

freezing and/or extreme temperatures).

Caution / Warning / Danger

Indicates a potential hazard. Failure to follow all warnings 

may lead to equipment damage, injury, or death.

Electrocution Danger

Alerts user to risk of potential of injury or death via 

electrocution.

Electrostatic Discharge (ESD)

Alerts user to risk of potential damage to product by ESD.

Personal Protective Equipment (PPE)

Always utilize the most appropriate PPE during 

installation and service of GF products.

Pressurized System Warning

Sensor may be under pressure, take caution to vent 

system prior to installation or removal. Failure to do so 

may result in equipment damage and/or serious injury.

Hand tighten only!

Hand Tighten Only

Overtightening may permanently damage product threads 

and lead to failure of the retaining nut.

Do Not Use Tools

Use of tool(s) may damage product beyond repair and 

potentially void product warranty.

Note / Technical Notes

Highlights additional information or detailed procedure.

DO NOT

FREEZE

Do Not Freeze

Products are temperature sensitive and may contain 

freezable liquids. Freezing damage to pH, ORP, and 

Chlorine electrodes voids product warranty.

74.4 mm (2.93 in.)

25.15 mm (.99 in.)

109.2 mm (4.3 in.)

72.6 mm (2.86 in.)

25.15 mm (0.99 in.)

26.4 mm (1.04 in.)

107.2 mm (4.23 in.)

26.4 mm (1.04 in.)

Description ............................................................................... 1
Warranty Information ................................................................ 2
Safety Information .................................................................... 2
Dimensions .............................................................................. 2

Specifications

 ........................................................................... 3

Sensor Preparation .................................................................. 4
Operation ................................................................................. 5
Calibration ................................................................................ 5
Maintenance ............................................................................. 6
Storage  .................................................................................... 7
Reconditioning ......................................................................... 8
Installation ................................................................................ 9
Mounting Position .................................................................... 9
Overview ................................................................................ 10
Troubleshooting ......................................................................11
Ordering Information .............................................................. 12

  Table of Contents

Summary of Contents for GF 3-2630-X

Page 1: ...ly and a secure connection Gold plated contacts and an O ring seal ensure a waterproof and reliable interconnect to the 2650 Amperometric Electronics Integrated temperature element for automatic tempe...

Page 2: ...ts user to risk of potential damage to product by ESD Personal Protective Equipment PPE Always utilize the most appropriate PPE during installation and service of GF products Pressurized System Warnin...

Page 3: ...ignet com for details Declaration of Conformity according to FCC Part 15 This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not c...

Page 4: ...sink is recommended 1 Remove the protective bottle from the end of the electrode 2 Remove the membrane cap from the front of the sensor Note When new sensors are shipped the membrane cap is not tight...

Page 5: ...le operating pressure must be less than 0 48 bar 7 psi Higher pressures will damage the electrode The electrode should not be used in water containing surfactants oils organic chlorine or stabilizers...

Page 6: ...injecting with electrolyte solution Slowly injecting the electrolyte solution into the sensor to avoid introducing air bubbles The electrode holds approximately 14 milliliters of solution Slowly fill...

Page 7: ...bottle with tap water added Storage periods more than 1 week Remove the membrane cap and internal electrolyte solution Rinse the sensor internal chamber with DI water or cold tap water drain and allow...

Page 8: ...7 11 Fill beaker with a 12 mm inch of the appropriate solution 12 Position or suspend the sensor 6 mm to 12 mm in to in above the appropriate solution DO NOT SUBMERGE THE SENSOR See Figure 2 13 Apply...

Page 9: ...t until fully seated Do Not Use Lubricant or Sealing Tape on Threads Do Not Overtighten Do Not Use Tools pipe tee pipe tee pipe tee pipe tee When using the chlorine panel flow cell it is not necessary...

Page 10: ...tions which help determine the specific application The predominant categories used in disinfection are Free Chlorine Total Chlorine and Chlorine Dioxide Free Chlorine is the sum of chlorine gas Cl2 h...

Page 11: ...resent in water See technical data Surfactants in water Remove surfactants and replace cap Membrane cap coated Clean or replace membrane cap Membrane cap loose Tighten or replace membrane cap pH outsi...

Page 12: ...1 to 20 ppm mg L 3 2632 1 159 001 767 Chlorine Dioxide electrode 0 02 to 2 ppm mg L Accessories and Replacement Parts Mfr Part No Code Description 3 2630 391 159 001 674 Free Chlorine electrolyte 30 m...

Reviews: