 2550 InsertionMagmeter

5.7  Calibration data

Pipe type

pipe pipe

gpm/fps lpm/fps

K A

K

A

size

id

pls/gal gpm/Hz

pls/l

lpm/Hz

PVC sched 80

3.5 in.

3.33 27.0803 102.51

55.39

1.08

14.63

4.10

PVC sched 40

3.5 in.

3.52 30.3488 114.88

49.43

1.21

13.06

4.60

steel sch 5S

3.5 in.

3.83 35.9843 136.22

41.68

1.44

11.01

5.45

steel sch 10S

3.5 in.

3.76 34.6087 131.01

43.34

1.38

11.45

5.24

steel sch 40S

3.5 in.

3.55

30.816 116.65

48.68

1.23

12.86

4.67

steel sch 80S

3.5 in.

3.36 27.7026 104.87

54.15

1.11

14.30

4.19

PVC sched 80

4 in.

3.79

35.089 132.83

42.75

1.40

11.29

5.31

PVC sched 40

4 in.

4.00 39.1289 148.12

38.33

1.57

10.13

5.92

steel sch 5S

4 in.

4.33 45.9819 174.06

32.62

1.84

8.62

6.96

steel sch 10S

4 in.

4.26 44.4251 168.17

33.76

1.78

8.92

6.73

steel sch 40S

4 in.

4.03 39.6786

150.2

37.80

1.59

9.99

6.01

steel sch 80S

4 in.

3.83 35.8343 135.65

41.86

1.43

11.06

5.43

PVC sched 80

5 in.

4.77 55.6521 210.67

26.95

2.23

7.12

8.43

PVC sched 40

5 in.

5.02

61.592 233.15

24.35

2.46

6.43

9.33

steel sch 5S

5 in.

5.35 69.9366 264.74

21.45

2.80

5.67

10.59

steel sch 10S

5 in.

5.30 68.6343 259.81

21.85

2.75

5.77

10.39

steel sch 40S

5 in.

5.05 62.3557 236.04

24.06

2.49

6.35

9.44

steel sch 80S

5 in.

4.81 56.7076 214.66

26.45

2.27

6.99

8.59

PVC sched 80

6 in.

5.71 79.7865 302.03

18.80

3.19

4.97

12.08

PVC sched 40

6 in.

6.03 89.0406 337.06

16.85

3.56

4.45

13.48

steel sch 5S

6 in.

6.41 100.489

380.4

14.93

4.02

3.94

15.22

steel sch 10S

6 in.

6.36 98.9267 374.48

15.16

3.96

4.01

14.98

steel sch 40S

6 in.

6.07 90.0473 340.87

16.66

3.60

4.40

13.63

steel sch 80S

6 in.

5.76 81.2466 307.55

18.46

3.25

4.88

12.30

PVC sched 80

8 in.

7.57 140.096 530.33

10.71

5.60

2.83

21.21

PVC sched 40

8 in.

7.94 154.408

584.5

9.71

6.18

2.57

23.38

steel sch 5S

8 in.

8.41 173.018 654.95

8.67

6.92

2.29

26.20

steel sch 10S

8 in.

8.33 169.822 642.85

8.83

6.79

2.33

25.71

steel sch 40S

8 in.

7.98 155.928 590.26

9.62

6.24

2.54

23.61

steel sch 80S

8 in.

7.63 142.328 538.77

10.54

5.69

2.78

21.55

PVC sched 80

10 in.

9.49 220.605 835.09

6.80

8.82

1.80

33.40

PVC sched 40

10 in.

9.98 243.625 922.23

6.16

9.75

1.63

36.89

steel sch 5S

10 in.

10.48 268.966 1018.2

5.58

10.76

1.47

40.73

steel sch 10S

10 in.

10.42 265.794 1006.1

5.64

10.63

1.49

40.24

steel sch 40S

10 in.

10.02 245.779 930.38

6.10

9.83

1.61

37.22

steel sch 80S

10 in.

9.75 232.712 880.92

6.45

9.31

1.70

35.24

PVC sched 80

12 in.

11.29 312.252

1182

4.80

12.49

1.27

47.28

PVC sched 40

12 in.

11.89 346.019 1309.8

4.34

13.84

1.15

52.39

steel sch 5S

12 in.

12.44 378.713 1433.6

3.96

15.15

1.05

57.34

steel sch 10S

12 in.

12.39 375.796 1422.6

3.99

15.03

1.05

56.90

steel sch 40S

12 in.

12.00

352.51 1334.4

4.26

14.10

1.12

53.38

steel sch 80S

12 in.

11.75 337.975 1279.4

4.44

13.52

1.17

51.18

Pipe type

pipe pipe

gpm/fps lpm/fps

K A

K

A

size

id

pls/gal gpm/Hz

pls/l

lpm/Hz

U.S. pipe data

PVC sched 80

2 in.

1.91 8.95858 33.912 167.44

0.36

44.23

1.36

PVC sched 40

2 in.

2.05 10.2576 38.829 146.23

0.41

38.63

1.55

steel sch 5S

2 in.

2.25 12.3379 46.704 121.58

0.49

32.12

1.87

steel sch 10S

2 in.

2.16 11.3896 43.115 131.70

0.46

34.79

1.72

steel sch 40S

2 in.

2.07

10.459 39.592 143.42

0.42

37.89

1.58

steel sch 80S

2 in.

1.94 9.20375

34.84 162.98

0.37

43.05

1.39

PVC sched 80

2.5 in.

2.29 12.8375 48.596 116.85

0.51

30.87

1.94

PVC sched 40

2.5 in.

2.45 14.6341 55.397 102.50

0.59

27.08

2.22

steel sch 5S

2.5 in.

2.71

17.965 68.005

83.50

0.72

22.06

2.72

steel sch 10S

2.5 in.

2.64 16.9969 64.341

88.25

0.68

23.31

2.57

steel sch 40S

2.5 in.

2.47 14.8228

56.49 101.20

0.59

26.55

2.26

steel sch 80S

2.5 in.

2.32 13.2101 50.006 113.55

0.53

30.00

2.00

PVC sched 80

3 in.

2.86 20.0796

76.01

74.70

0.80

19.73

3.04

PVC sched 40

3 in.

3.04 22.6531 85.752

66.22

0.91

17.49

3.43

steel sch 5S

3 in.

3.33 27.2107

103

55.13

1.09

14.56

4.12

steel sch 10S

3 in.

3.26 26.0162 98.483

57.66

1.04

15.23

3.94

steel sch 40S

3 in.

3.07

23.042 87.224

65.10

0.92

17.20

3.49

steel sch 80S

3 in.

2.90 20.5876 77.933

72.86

0.82

19.25

3.12

Summary of Contents for SIGNET 2550

Page 1: ...es automatic temperature compensation resulting in outputs that are accurate within 2 of actual flow rate The bipolar electronic design and the 10000 MΩ input impedance reduce galvanic formation on the electrodes and minimize coating problems The isolated current output provides an universal signal to recorders valves process control and data acquisition devices The open collector frequency output...

Page 2: ... Inlet Outlet 90 elbow Inlet Outlet Measure and record the interior diameter of the pipe This value will be required to calibrate the 2550 Interior diameter ________________________________ 3 3 Sensor Installation with tool WARNING Do not remove safety ring or adjustment nut from sensor The installation tool 3 2550 355 simplifies installation and insures proper insertion depth for maximum accuracy...

Page 3: ...aptive outer cover screws 1 lift off outer cover 2 then loosen two captive screws 3 and remove access plate 4 A wiring diagram is located on the inside of the access plate Five terminal strips are available TS 3 Analog output 4 to 20 mA or 0 to 20 mA output terminal 1 positive R terminal 2 negative R 18 to 22 AWG wire recommended TS 4 Serial communication Future expansion not available in this mod...

Page 4: ...oop Without moisture drip loop Careful cable routing and sealed ports can help prevent water intrusion 3 In plastic piping systems the fluid carries significant levels of static electricity that must be grounded for best magmeter performance Since plastic pipe is not grounded as metal pipes are extra steps must be taken Identify the places where the fluid is in electrical contact with external met...

Page 5: ...played user calibration displayed This basic operating procedure repeats throughout the 2550 program 1 Press RUN EDIT to enter edit menu 2 Press to move to a specific menu item 3 Press ENTER key to select the item for editing 4 Press ENTER to edit the value selection 5 Press ENTER to store the new value selection 6 Press to select another menu item or 7 Press RUN EDIT to return to normal operation...

Page 6: ...r diameter You must enter the precise interior diameter of your pipe as measured during the installation process Entry is made in inches when the dimension entered is less than 40 and automatically switches to millimeters when the dimension entered is greater than 40 To change the id selection enter the access code section 5 2 1 then press the down arrow until the display shows 3 2 1 4 7 6 5 8 9 1...

Page 7: ...tion 5 2 1 then press the down arrow until the display shows ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER 8 5 4 PerformanceFunctions The next five main menu functions help to tailor the magmeter signals to your specific environment 5 4 1 Sensitivity The sensitivity function limits the amount of reference level noise detected by the Magmeter input circuit Use the St...

Page 8: ...ow to change the setting to 2 The factory default setting for viscosity is 1 3 2 1 ENTER ENTER Step Press To display Viscosity ranges 1 1 cp water 2 2 cp 3 4 cp 4 8 cp 5 N A future expansion Step Press To display Arrow keys advance main menu function Run Edit key returns to normal operation 5 4 4 AC Noise Filter Select 50 Hz or 60 Hz rejection filter according to the AC power standard in your area...

Page 9: ...ground Use the Sensitivity adjustment section 5 4 1 to compensate and check the grounding requirements section 3 2 The standard flow deviation StdF is an overall indication of the stability of the flow signal It incorporates the StdE as 1 2 3 RUN EDIT ENTER well as mechanical factors such as unstable flow profiles misaligned sensors and coated electrodes StdF is displayed as a percentage of flow r...

Page 10: ...40S 8 in 7 98 155 928 590 26 9 62 6 24 2 54 23 61 steel sch 80S 8 in 7 63 142 328 538 77 10 54 5 69 2 78 21 55 PVC sched 80 10 in 9 49 220 605 835 09 6 80 8 82 1 80 33 40 PVC sched 40 10 in 9 98 243 625 922 23 6 16 9 75 1 63 36 89 steel sch 5S 10 in 10 48 268 966 1018 2 5 58 10 76 1 47 40 73 steel sch 10S 10 in 10 42 265 794 1006 1 5 64 10 63 1 49 40 24 steel sch 40S 10 in 10 02 245 779 930 38 6 1...

Page 11: ...33 54 505 44 11 23 5 34 2 97 20 22 PVDF bar 10 250 234 8 209 19 791 78 7 17 8 37 1 89 31 67 PVDF bar 16 63 57 12 33 46 661 121 67 0 49 32 15 1 87 PVDF bar 16 75 67 8 17 44 66 019 86 00 0 70 22 72 2 64 PVDF bar 16 90 81 4 25 14 95 161 59 66 1 01 15 76 3 81 PVDF bar 16 110 99 4 37 49 141 9 40 01 1 50 10 57 5 68 PVC bar 10 63 57 12 33 46 661 121 67 0 49 32 15 1 87 PVC bar 10 75 67 8 17 44 66 019 86 0...

Page 12: ...x 25 130 Hz 5 2 ft s 130 Hz Unit GPM Display 120 GPM 120 GPM 130 Hz A 120 130 0 92 K 60 0 92 65 2 6 Ordering Information Mfr Part No Code Description 3 2550 100 110 159 000 294 Insertion Magmeter with 2 in NPT Fitting 3 2550 100 110T 159 000 632 Insertion Magmeter with 2 in NPT Fitting and Installation Tool 3 2550 100 111 198 840 024 Insertion Magmeter with 2 in ISO Fitting 3 2550 100 111T 198 840...

Reviews: