30
E
Maintenance
You
must not try to repair
the
JRG CleanLine Filter.
Backwashing the filter:
Ensure a sufficiently large drain line
after the drain pipe. At a primary pres-
sure of 1‘600 kPa (16 bar) a discharge
rate of 1.25 l/s is to be expected.
For information regarding further
flushing rates at lower primary pres-
sure, see installation instructions.
Turn the hand wheel
8
clock-
wise, the LED
10
will light, until
water leaks from the drain pipe.
Now the first filter chamber is
flushed:
Flushing time 3-5 seconds.
Repeat this process until all eight filter
chambers are flushed. After the eighth filter
chamber the hand wheel palpably locks, the LED
10
goes out. The flushing process is complete.
If the filter is heavily soiled, we recom-
mend repeating the previously described
flushing process.
Make sure water stops leaking from the
drain pipe after completing the flushing.
If water is still leaking from the drain
pipe, fully repeat the above-described
flushing process.
After flushing, turn the month ring
7
to match
the current month (month digit pointing upwards).
This enables you to determine when the filter
was flushed last.
Malfunctions
In case of persistent problems, please
contact your local plumbers.
7
8
Summary of Contents for JRG CleanLine 1870.025
Page 9: ...9 1870 025 032 F 9 16 Notice d utilisation et d entretien JRG CleanLine Filtre...
Page 17: ...17 Istruzioni d uso e manutenzione JRG CleanLine Filtro 1870 025 032 I 17 24...
Page 25: ...25 1870 025 032 E 25 32 Operating and maintenance instructions JRG CleanLine Filter...
Page 33: ......
Page 34: ......
Page 35: ......