![GF JRG 7045.240 Operating And Maintenance Instructions Manual Download Page 56](http://html1.mh-extra.com/html/gf-0/jrg-7045-240/jrg-7045-240_operating-and-maintenance-instructions-manual_2219254056.webp)
56
E
Maintenance
Exchange the valve cone:
– Shut off the garden-pipe valve
– Open the garden valve so that any residual water can flow out
– Hold the valve body before loosen and remove the top element
– Release set screw and remove spindle with valve disk (2)
– Insert flat spanner into vice and carefully release the plastic
valve-cone from its seating with a jerk movement (picture)
– Fix the new plastic valve cone (with spring) into its seating by
lightly striking with a rubber hammer
– Insert the spindle with valve disk (2) as far as it will go into the
valve top (6) and tighten the set screw
– Insert carefully the spindle with valve disk (2) into the valve
body (3), hold the valve body and screw in the
– Now open the garden-pipe valve
– Check that all works properly
Spare part set (I. Nr. 35 56 409 10) consisting of:
– Plastic valve cone
– Spring
– O-ring