Instruction manual
Troubleshooting
50
12
Troubleshooting
Fault
Possible cause
Troubleshooting
Leak at pipe
Leaking connections
Check bonding or welding
and repair, if necessary
Check gaskets and
replace, if necessary
Leak between top part and
base part
Retaining ring not
correctly inserted
Position the retaining ring
so both projections of the
retaining ring lie in the
notches of the base part
Bonnet assembly (top
part) loose
Retighten bonnet
assembly (top part)
Leak at bonnet assembly
(top part)
Piston screw loose
Retighten piston screw
Diaphragm damaged
Replace diaphragm, see
Chapter 11
Control element
(diaphragm, piston,
sealing element) defective
Replace cartridge.
Inertia too high, setpoint
value not reached
Valve undersized
Check valve dimensioning
(k
vs
value)
Valve does not react to
compressed air
Valve is not dimensioned
for compressed air, and
therefore has no
compressed air
connection
Remove compressed air
and select other valve
(e.g. pneumatic diaphragm
valve) for the application
Summary of Contents for 582 High Purity