UFO-NT
68
Service menu
27.3.14 Language
Name
Setting values
Explanation
Language
German
English
French
Swedish
27.4 DPS (DPS)
The DPS can be used for commissioning and servicing, mat. no. 151524:
à
for changing the drive parameters
à
for "teaching" the drive
à
for diagnosis
Mode of operation
Service mode
N a
Night
×
Cancel and return to first
menu level
OFF
1
2
3
4
ls
Exit only
Confirm
a U
Automatic
Scroll up
Increase value
D O
Hold open
Scroll down
Reduce value
O f
OFF
+
simultaneously
Change
2-leaf operation
1-leaf operation
–
–
Service button (1)
+
simultane-
ously
Change mode of operation / service mode
1
Service button
2
Position unknown
3
Illuminated for maintenance
4
Lights up at 1-leaf operation
27.5 Service menu DPS
à
Changing to the service mode is possible in the NA, LS, AU and DO modes of operation.
à
If no key is pressed in service mode for a period of 2 minutes, the mode of operation automatically changes.
à
In service mode, the door remains in operation in the current mode of operation (not when teaching is activated).
1 Menu
DPS Parameter
Setting values
Explanation
O T
Opening time
03...
04
... 06... 25
in s;
Opening time
*)
with automatic opening. Setting pursuant to the
table in the Powerturn installation instructions.
C T
Closing time
05
… 06 … 25
in s;
fb
Leaf width
06…
11
in mm × 100;
Influences the forces at the main closing edge.
T6
Door weight
01,
02
in kg × 100 ;
Influences the safe speed.
pU
Push and Go
00
01 … 20
0 %: No Push And Go
1–20 %: Push And Go
Response range referenced to maximum opening range (=100)
sc
Latching action
closing
00
… 10
12 … 20
25 … 50
Sets the speed at which the drive moves to the closed position
shortly before closing. This is required e.g. for operation with a
motor lock. Latching action also applies for manual passage.
Summary of Contents for UFO-NT F
Page 1: ......
Page 7: ...UFO NT 7 Supply terminals 4 Supply terminals DCU800 1 2 24V GND 6 1 RS485 passive leaf 2 FREE ...
Page 79: ...UFO NT 79 ...