UFO-NT
66
Service menu
Name
1 Sub-menu
2 Sub-menu
Explanation
Outputs
PA1
off
PA2
off
TOE
off
TEST
off
FAN
off
MAG
off
Fault memory
Current faults
Error 1
Cause 1
Cause 2
Error 2
Cause 1
Cause 2
Error 3
Cause 1
Cause 2
Error 4
Cause 1
Cause 2
Old faults
Error 1
Cause 1
Cause 2
Error 2
Cause 1
Cause 2
Delete current errors
no
yes
Clear old faults
no
yes
Configuration
Drive
Ser. no. 000000000000
OEW left ?xyz
Mot.Resist: 1770mOhm
Curr.M.Res: 0mOhm
Control
Type Powerturn
Date of err. CW xy xzyx
SVN 1280:161711 (Example)
27.3.8 Standard values
Name
1 Sub-menu
2 Sub-menu
Explanation
Standard values
no
yes
Values are set to standard set-
tings Position, WIO wall blank-
ing, and opening angle are re-
tained. Fault memory is deleted.
A teaching run and initialisation
run are not necessary.
27.3.9 Reset DCU8
Name
1 Sub-menu
2 Sub-menu
Explanation
Reset DCU8
no
yes
Fault memory is deleted. Posi-
tion and opening angle are not
deleted. The processor restarts.
A teaching run is not necessary,
an initialisation run is necessary.
27.3.10 Start teaching
Name
1 Sub-menu
2 Sub-menu
Explanation
Start teaching
1-leaf Teaching
Starts the teaching procedure.
For the procedure, see chapter 20.2.
2-leaf Teaching