GEZE IQ box KNX Commissioning Manual Download Page 3

GEZE IQ Box KNX

3

 

About this document

The Commissioning manual is a supplement to the addendum of the IQ box KNX. It provides comprehensive 

documentation about the commissioning and setting parameters of the GEZE IQ box KNX. 

Knowledge of the KNX Bus System and of the KNX ETS software from version 4.0 is required for setting the param-

eters and for integrating the IQ box KNX into a KNX bus system.

1.1  Product description and compatibility

The IQ box KNX makes the control and monitoring of the GEZE IQ windowdrives (Slimchain, Powerchain, E 250 NT, 

Power lock, etc.) via the KNX-bus system possible. The drives can be moved to the required positions and the cur-

rent drive position and various drive states can be requested. Two additional binary inputs can be used either for 

direct operation (e.g. manual push buttons) or as bus inputs. Configuration is done using the KNX software ETS 

(from version 4.0). The ETS product database can be downloaded via the internet from www.geze.com or directly 

from www.iq-box-knx.geze.de. 

     

The IQ windowdrives used for operating the IQ box KNX must have software version 3.0 or higher. 

The SW ver-

sion of the drives is shown on the packaging label and on the identification plate. 

1.2  Further documents

 

à

IQ box KNX leaflet

The leaflet is enclosed with the IQ box KNX and contains the most important product information and instruc-

tions about the electrical connection and about commissioning of the IQ box KNX. 

 

à

IQ windowdrives installation instructions

The installation instructions are enclosed with the IQ windowdrives and contain information about installing 

the IQ windowdrives.

 

à

IQ windowdrives wiring diagram

The wiring diagram is also enclosed with the IQ windowdrives and contains information about the electrical 

connection of the IQ windowdrives.

All documents can also be found on the internet at www.geze.com.

1.3  Symbols and illustrations

Warning notices

Warning notices are used in these instructions to warn you of property damage and personal injury.

 

X

Always read and observe these warning notices.

 

X

Follow all measures that are labelled with the warning symbol and warning word .

Warning 

symbol

Warning word Meaning

 

ATTENTION

Danger to persons. 

Non-compliance can result in death or serious injuries.

 

CAUTION

Danger to persons. 

Non-compliance may lead to minor injuries.

     –

CAUTION

Information to prevent property damage, to understand or optimise the operation 

sequences.

More symbols and illustrations

Important information and technical notes are highlighted to explain correct operation.

Symbol

Meaning

     

means “important note”

       

means “additional Information”

 

X

 

Symbol for an action: there is something you must do here.

If there are several actions to be taken, keep to the given order.

 

Summary of Contents for IQ box KNX

Page 1: ...IQ box KNX 166560 00 EN Commissioning manual Prog Ru n...

Page 2: ...diagram 6 5 Test operation and commissioning of the IQ windowdrives 7 5 1 Test operation 7 5 2 KNX commissioning 7 5 2 1 Load ETS product database IQ box KNX 7 5 2 2 Assign physical address of the IQ...

Page 3: ...is enclosed with the IQ box KNX and contains the most important product information and instruc tions about the electrical connection and about commissioning of the IQ box KNX IQ windowdrives install...

Page 4: ...k Ensure that the connection to the power supply is only carried out by a qualified electrician The power con nection and safety earth conductor test must be carried out in accordance DIN VDE 0100 610...

Page 5: ...4 V external 3 2 2 IQ box KNX top hat rail fitting to top hat rail IQ box KNX top hat rail Power supply NT 1 5 4 2 A 24 V HS GEZE surface housing ID 152010 with 35 mm top hat rail for 6 modules Prog R...

Page 6: ...mounting wiring diagram 8 9 10 11 12 A B S L GND 24V 33 32 COM A S LIN B S L L A B S A B 230V AC Fenster window 4 24 V DC max 6 A 3 5 7 6 IQ box KNX KNX KNX KNX 1 1 2 4 2 IQ box KNX top hat rail wirin...

Page 7: ...first time the closing position of the window is detected during the first closing procedure and is saved automatically Should the drive reverse after reaching the closing position drive opens by app...

Page 8: ...ndow Closed State 1 002 C T 1 Bit OUT T 15 Window Not closed State 1 002 C T 1 Bit OUT T 16 Window Do open State 1 002 C T 1 Bit OUT T 17 Window Do close State 1 002 C T 1 Bit OUT T Alarm 21 Alert Saf...

Page 9: ...cure windows against jamming a leaf speed of 5 mm s can be required within the framework of a safety analysis Drive noise increases as speeds increase Operation Interval ventilation Settable step widt...

Page 10: ...lation speed Not suitable for RWA Alarm Wind alarm Rain alarm For wind alarm a binary wind alarm and a wind alarm as threshold value in m s can be selected After the end of the wind rain alarm and a s...

Page 11: ...time 1 second 5 seconds 10 seconds 30 seconds 1 minute 2 minutes 5 minutes 10 minutes 20 minutes 30 minutes Open window Off time 1 second 5 seconds 10 seconds 30 seconds 1 minute 2 minutes 5 minutes...

Page 12: ...ventilation Disabled Enabled Window position 0 100 50 4 Window Gap ventilation Trigger Time ventilation Disabled Enabled Window position 0 100 50 5 Window Time ventilation Trigger Ventilation time 5 1...

Page 13: ...omatic Lock Switch Locked to close Unlock Via object 9 Automatic Lock Switch Until timeout Locking time min 1 300 30 9 Automatic Lock Switch Locked to open and close Unlock Via object 9 Automatic Lock...

Page 14: ...d state Disabled On change 12 13 14 15 16 17 Window Position between State Window Opened State Window Closed State Window Not closed State Window Do open State Window Do close State Cyclic Cycle time...

Page 15: ...action on safety alert Close window Open window Type wind alert Binary 23 Alert Wind alert Switch Threshold Threshold windspeed m s 2 30 4 22 Alert Wind speed value m s Behavior after wind rain alert...

Page 16: ...without self locking Close 32 Button 1 Cl 33 Drive com mand Step Stop Position Window position 0 100 50 33 Button 1 Cl 33 Position Value Button 2 Cl 32 Disabled Lokal Drive type Tip op eration with se...

Page 17: ...ion Disabled On change 41 Service Check unit State Error information Disabled Error unit Send condition On change 42 Service Error unit State Cyclic Cycle time min 1 255 50 Error collection Send condi...

Page 18: ...n group Local push button Expanded function examples KNX Easy ventilation controls All basic functions can be realised through the grouping of several windows centrally for the entire ventilation grou...

Page 19: ...tion examples KNX Automatic closing when the air conditioning is activated If the air conditioning is activated the windows are closed automatically Blocking of the manual opening As long as the air c...

Page 20: ...idity are exceeded intelligent ventilation is ap plied until the air quality returns to the requirements Controls depending on times of day and usage Ventilation at certain times depending on room us...

Page 21: ...ox KNX Check length of the connection cable to the drive The overall cable length between IQ box KNX and window must not exceed max 15 m Check software version of the drives on the identification plat...

Page 22: ...GEZE IQ Box KNX 22...

Page 23: ...GEZE IQ Box KNX 23...

Page 24: ...om cn France GEZE France S A R L E Mail france fr geze com www geze fr Hungary GEZE Hungary Kft E Mail office hungary geze com www geze hu Iberia GEZE Iberia S R L E Mail info geze es www geze es Indi...

Reviews: