79
Faults and troubleshooting
Gewiss
Code
Error description
Solution
Position
Error 12
The miniature circuit breaker
of the relative Schuko/side
socket-outlet is OFF.
Reset correct miniature circuit
breaker operation. If the error
persists, replace the device.
Error 13
Short-circuit detected on the
CP signal
The station detects a short-
circuit between the CP signal
and earth.
Remove the cable and try again.
If the error persists, replace
the cable
Station
OFF
The electronic board is not
receiving the power supply it
needs in order to work
Check the power supply
upstream of the station.
Check the circuit breaker
protection in the board
(to protect the electronic card)
is working properly.
Check the 12V power supply
unit of the electronic card is
working properly.
In the case of products connected to the JOINON platform, or if the maintenance package has been purchased, call the
FreePhone number 800 123 325.
In all other cases where technical support is required, call GEWISS SAT customer service.
7.55.4.515.2 - Installation and Operation Manual
Installation and Operation Manual
IT
EN
FR
ES
DE
RO
HU
NL
Summary of Contents for JOINON
Page 2: ......
Page 4: ...4 Gewiss 7 55 4 515 2 Manuale d installazione e uso ...
Page 46: ...46 Gewiss 7 55 4 515 2 Installation and Operation Manual ...
Page 88: ...88 Gewiss 7 55 4 515 2 Manuel d installation et usage ...
Page 130: ...130 Gewiss 7 55 4 515 2 Manual de instalación y uso ...
Page 172: ...172 Gewiss 7 55 4 515 2 Handbuch für Montage und Betrieb ...
Page 214: ...214 Gewiss 7 55 4 515 2 Manual de instalare și utilizare ...
Page 256: ...256 Gewiss 7 55 4 515 2 Használati és karbantartási kézikönyv ...
Page 298: ...298 Gewiss 7 55 4 515 2 Installatie en gebruikshandleiding ...
Page 340: ......