Faults and troubleshooting
Gewiss
Code
Error description
Solution
Position
Error 6
Error in the control of the socket-
outlet locking motor (it doesn't
switch from the OPEN to the
CLOSED position)
Manually check the mobility
of the pin by moving the red
lever on the back of the type 2
socket-outlet locking motor.
Error 7
Error in the control of the socket-
outlet locking motor (it doesn't
switch from the CLOSED to the
OPEN position)
Manually check the mobility
of the pin by moving the red
lever on the back of the type 2
socket-outlet locking motor.
Error 8
The energy meters are no
longer communicating with the
electronic board
Check the connection of the
Modbus line.
Check the power supply to the
energy meters.
Check the energy meters are
working properly.
Check that the component
on the Modbus line is
numbered correctly.
7.55.4.515.2 - Installation and Operation Manual
Installation and Operation Manual
IT
EN
FR
ES
DE
RO
HU
NL
Summary of Contents for JOINON
Page 2: ......
Page 4: ...4 Gewiss 7 55 4 515 2 Manuale d installazione e uso ...
Page 46: ...46 Gewiss 7 55 4 515 2 Installation and Operation Manual ...
Page 88: ...88 Gewiss 7 55 4 515 2 Manuel d installation et usage ...
Page 130: ...130 Gewiss 7 55 4 515 2 Manual de instalación y uso ...
Page 172: ...172 Gewiss 7 55 4 515 2 Handbuch für Montage und Betrieb ...
Page 214: ...214 Gewiss 7 55 4 515 2 Manual de instalare și utilizare ...
Page 256: ...256 Gewiss 7 55 4 515 2 Használati és karbantartási kézikönyv ...
Page 298: ...298 Gewiss 7 55 4 515 2 Installatie en gebruikshandleiding ...
Page 340: ......