___________________________________________________________________________
GP+GP – Maintenance book Pag.
39 of 43
PUMP TYPE GP/M - 45/65
1 VACUUM INLET
2 OUTLET TO
ATMOSPERE
3 OIL DISCHARGE CAP
4 OIL SIGHT GLASS
5 OIL FILL UP CAP
6 MOTOR WIRING BOX
PUMP TYPE
GP 45
GPM 45
GP 65
GPM 65
Speed:
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
Displacement m3/h
45
54
45 54 65 78 65 78
Ultimate vacuum
mbar
10
10
0,5
0,5
10
10
0,5
0,5
Ultimate vacuum with gas ballast mbar
14 14 1,5 1,5 14 14 1,5 1,5
Noise level
(without gas ballast)
Kg./h
0,3
0,7
0,3
0,7
1
1,2
1
1,2
Max water steam quantity
accetable with gas ballast
db(A)
63 68 63 68 64 69 64 69
Standard voltage *
V
230/400
460
230/400
460
230/400
460
230/400
460
Motor
power
kW 1,1 1,5 1,1 1,5 1,5 1,8 1,5 1,8
R.P.M.
r.p.m.
1450 1750 1450 1750 1450 1750 1450 1750
Weight ( with oil)
Kg.
42
48
Oil quantity
litri
2-2,5
2-2,5
Suction outlet
1” Gas
1” Gas
Exhaust outlet
1” ¼ Gas
1” ¼ Gas
Dimensions ( mm )
A 620
700
B
265
265
C
310
310
D
185
185
E
25
32
F
240
240
G
90
90
H
210
210
L
55
55
M
170
170
P
170
170
Q
175
175
R
12
55
S
240
240