___________________________________________________________________________
GP+GP – Maintenance book Pag.
16 of 43
C.5
Electric motor disassemblig
WARNING
Check that motor cannot start and the electric main is off
For disassembling the electric motor unscrew the three screws which are coupling pump to turret.
Pull out the joint with fun from the motor’ shaft
Unscrew the 4 fixing screws from motor turret
After check out and replacement of the electric motor, reassemble all operating inversaly
Beware
In case of motor replacement, check the pump rotating sense following the described instructions
stated at B 4 paragraph.