(Fig. 6/order no. 8830601). When connec-
ting multiple handsets, it is sufficient if you
are using a single power supply for all stati-
ons. However, this power supply has to be
the one which is the closest to the outdoor
panel. In order to communicate internally,
press the button. This will trigger a
collective call and establish a connection to
the remote handset which is being picked up
first (for approx. 30 sec.). As long as there’s
an internal connection, the voice contact to
the outdoor panel is locked. The intercom
function is interrupted in case there is an ex-
ternal call coming in.
Receycling instructions
This device may not be disposed
of with unsorted household waste.
Owners of old devices are required by
law to dispose this device correctly.
Contact your twon council for further infor-
mation.
Specifications
Handset
(8830601)
Specifications
Dimensions
70[W] x 230[H] x 40 [D]mm
Power Supply
DC18V / 1,5A
Power Consumption
Max. 2W
Connection
System
2-wires
Sounds
1
Max. Distance/ wire to be used
Min. diameter of cable between last
handset and outdoor panel
up to 25m: ø 0,6mm-1,0mm
up to 100m: ø 1,0mm-1.5mm
Protection
type
IP
20
Mains
adapter
Specifications
Power Supply
230 V~, DC 18V, 1,5A
Outdoor panel (8831301)
Specifcations
Dimensions
95[W] x120[H] x 30 [D]mm
Current
DC12V (via indoor unit / handset)
Installation type
Outdoor- / Indoor unit : 2-wires
Door strike
Current 12V DC / max. 1.0A
Gate motor
Dry contact / closing time ca. 3 sec.
Type of installation
Wall mount
Protection
type
IP
54
Operating temperature
-10 ˚C - 45 ˚C
10
Technical and design features may be subject to change without notice.
GEV_2_fam_RZ_luensee_print.indd 10