indoor unit).
Tip:
Seal the joints between the outdoor unit
and the wall from three sides with silicone.
Let the joint on the bottom open to decrease
the likelihood of condensation.
Mounting the indoor unit (Fig. 4a and 4b)
First, open the indoor unit for this purpose,
go with a suitable screw driver on the right
bottom in the recess and pry through slight
leverage the top of the lower shell. Mount
the lower shell with four screws at the desi-
gnated place on the wall. Now connect the
wires as shown in figure 5. or 6-depending
on your desired level of expansion.
Installation of the handset/
installation of outdoor panel/
caption of the badge
Connecting the handset.
See figures 5 or 6-depending on your desired
level of expansion. To avoid problems high-
and low-voltage cables should never be in
the same cable conduit. Connect the cables
as shown in the figures described.
Connecting the handset to the outdoor
panel: Connect the power supply with the
inside socket. Connect „L +“ and „L -“ of the
handset with the terminals „L +“ and „L -“ of
the outdoor panel.
Connecting an electric door/or gate strike.
You can optionally include an electric door
and/or gate opener in this system. For the
connection diagram see Figure 5 or 6.
Caption of the name plate: Remove the
cover of the bell in which you lever it by
using a thin tool and carefully push it inside
the notches (fig. 7/A).
Set Up/Operation
Pressing on the push button of the outdoor
panel, raises a signal on the handset (max. 6
times within 30 sec.). You can now pick up
the phone and speak with the guest for a
maximum of approx. 90 sec. To operate the
electric door opener, briefly press (1 sec.)
the
button on the indoor unit. Important:
It is essential that you use a door opener
which has a memory function. Regarding
the connection instructions see connection
diagram 5 or 6. As a suitable electric door
opener, we recommend such as item no.
007680 (110 mm) or 007697 (250 mm) from
our GEV product range.
For connecting an electric gate opener
connect the terminals „GATE“ „GATE“ of the
outdoor panel and the two corresponding
terminals (varies- depending on the manuf-
acturer. Consult the manual of your gate
drive engine) to your gate engine (terminals
„GATE“ „GATE“ are dry contacts).
In case you have connected an external gate
drive, enable this by a three-second press
on the
button on the phone.
Important:
The functions can be exe-
cuted only when the active unit and
after lifting the handset.
Additional information
You have the option to connect up to
three additional interior handsets in parallel
Abb./Fig. 7
A
GB
9
GEV_2_fam_RZ_luensee_print.indd 9
06.06.14 10:56