Range test
Set the
TIME
controller to minimum, the
LUX
controller to „Sun“ and the
METER
controller to
maximum
(Fig. E)
. If the motion detector is
connected to a separate switch, switch it on. A
self-test, lasting 60 seconds, will now begin. The
sensor LED and connected system (e.g. a light)
will remain on throughout the test. When the
system goes out, the range test will begin:
whenever movement is detected, the system will
switch on for approx. 6 seconds, regardless of the
ambient brightness. Perform this test to establish the
fi eld of detection. Set the
METER
controller to the re-
levant setting. Once the device has been successfully
set, you can programme additional settings.
Additional settings (Fig. E)
LUX
twilight switch approx. 5 - 1000 Lux. When
you turn the
LUX
controller (the lowest
setting is „Moon“), the sensor LED will
light up if movement is detected and if the
ambient brightness is reached or exceeded.
This enables you to defi ne the current light
intensity value (setting aid).
TIME
sets the duration of the ON period, approx.
6 seconds to 5 mins.
Recycling instructions
This device may not be disposed of with the
unsorted household waste. Owners of old
devices are required by law to dispose of
this device professionally. Contact your town
council for further information.
7
6
D
GB
F
NL
I
E
S
N
DK
FIN
RUS
GR
LV
LT
PL
RO
SL
O
SK
CZ
TR
H
Troubleshooting – Practical tips
Problem Cause
Remedy
Motion detector switches
• Detection range setting
• Adjust detection area by
the light on too late
• Movement from the front
turning the sensor
Motion detector fails to
• Motion detector is mounted too low
• Mount higher
achieve maximum range
• Diff erence in temperature between heat source
and surroundings is not big enough
Troubleshooting – Practical tips
Problem Cause
Remedy
Motion detector switches
• Constant thermal movement:
light on constantly
There are areas within detection range that are
or when not necessary
not supposed to be monitored, e.g. footpaths,
roads, trees etc. Unexpected changes in heat
sources caused by storms, rain or fans.
The
infl uence of direct / indirect sunlight
Technical data
Field of detection
360° with a beam angle of 100°
Range
approx. 3 m
Time adjustment
freely adjustable from approx. 6 sec. to 5 min.
Twilight switch
freely adjustable from approx. 5 to 1,000 Lux
Mains connection
230 V ~, 50 Hz
Switching capacity
230 V , 5 A (fl oating)
Power consumption
approx. 1.4 W
Protection type
IP 44 for the sensor, IP 20 for the power section
Protection class
II
Subject to technical and design changes without prior notice.