GET GPACU9W User Instructions Download Page 8

 
Exhaust Air Ducting 

This can either be done as a temporary installation through an open door or window, or as a 
permanent installation through a wall. 

Temporary Installation 

1)  Attach one end of the vent hose (item A) to the exhaust air outlet of the air conditioner 

using an end fitting (item B). 

2)  Attach the other end of the vent hose (item A) to the window / door fitting (item C) by 

means of an end fitting (item B). 

3)  Put the window / door fitting (item C) through an open window or door, keeping the 

opening to a minimum.      

 
 

Permanent installation 

Whilst there is a wall fitting and wall fitting cap supplied with the air conditioner, it is 
recommended that use is made of the separately available venting kit (details available from 
the Helpline) which also contains an external grille and a hose to pass through the wall. 

1)  Make a suitable size hole through the external wall to accept the hose in the wall 

venting kit.  

2)  Secure the flexible ducting in the wall venting kit to the wall fitting using cable ties. 
3)  Pass the flexible ducting through the hole in the wall from the inside. 
4)  Fix the wall fitting to the surface of the internal wall using suitable wall plugs and 

fixing screws. 

5)  Attach the external grille to the other end of the flexible ducting using cable ties and 

fix to the outside wall using suitable wall plugs and fixing screws. 

6)  Attach one end of the vent hose (item A) to the exhaust air outlet of the air conditioner 

using an end fitting (item B). 

7)  Attach an end fitting (item B) to the other end of the vent hose and fit it into the wall 

fitting. . 

8)  When not in use, cover the hole with the wall fitting cap.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for GPACU9W

Page 1: ...USER INSTRUCTIONS FOR GET PORTABLE 9k BTU AIR CONDITIONER MODEL No GPACU9W ...

Page 2: ...CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Troubleshooting Maintenance Energy Saving Tips Specification ...

Page 3: ...s a multi functional room air exchanging air processing appliance designed to offer you the functions of Air Conditioning Dehumidifying Independent Fan This manual will provide you with valuable information necessary for the proper care and maintenance for your new appliance Read these instructions fully before operating the unit and retain them for future reference If properly maintained your app...

Page 4: ...ring replacement ensure that equivalent rated and approved components are used See plug replacement details below 9 IMPORTANT If this unit is sited in a room containing a fuel burning appliance the installer must ensure that the air replacement is sufficient for both the unit used as an air conditioner and the fuel burning appliance PLUG REPLACEMENT If the plug is damaged and requires replacement ...

Page 5: ...Warning In order to ensure the long reliable and safe functioning of the air conditioner the following safety points should be observed ...

Page 6: ...Identification of Parts Front View Rear View ...

Page 7: ...e vent hose to reach outside the room The air intake should be a minimum distance of 50cm from any object Do not install the unit underneath desks or inside cupboards as this will restrict the operating air flow Ensure that there are no obstructions to the air intake or air outlet Ensure that the air intake is not being blocked by curtains or similar objects The end of the vent hose should not be ...

Page 8: ...available from the Helpline which also contains an external grille and a hose to pass through the wall 1 Make a suitable size hole through the external wall to accept the hose in the wall venting kit 2 Secure the flexible ducting in the wall venting kit to the wall fitting using cable ties 3 Pass the flexible ducting through the hole in the wall from the inside 4 Fix the wall fitting to the surfac...

Page 9: ...the machine is full and the machine will stop If after draining the tank the warning light remains on this could indicate that there may be a fault with the machine If this is the case do not attempt to operate the machine and call the service number Mode Control Model GPACU9W The mode control has three settings Cool Dehumidifier Fan Repeated pressing of the mode button will select the modes in or...

Page 10: ...press Timer and then the Timer Temp Adjust buttons to select the number of hours you would like the unit to run until it automatically shuts off The green timer LED will remain lit Timer mode b Auto Turn On Switch the machine on using the Power button so that the machine is running and the desired mode is selected Press the Power button again to put the machine into stand by mode With the machine ...

Page 11: ... Drain the water tank Air conditioner runs intermittently Malfunction Surrounding temperature is too high or too low Heat exhaust hose is blocked Contact the service centre Check the hose Air conditioner functions but the room is not cooled Window or door is left open in the room There is heat source in the room or too many people in it Filter is too dirty Temperature settings are too high Close a...

Page 12: ...ergent to remove stubborn stains End of season maintenance 1 Remove the water draining plug located at the rear bottom of the air conditioner replace the plug after the condensation has been drained from the water tank 2 Turn on the fan operation for a period of time to dry interior of the air conditioner 3 Remove the power cord plug from the socket and store the lead on the hooks at the back of t...

Page 13: ...ake sure you check and clean the filter each week If the filter is not kept clean it can increase your power consumption and reduce the cooling efficiency Take note of the following points Avoid direct sun light on the unit through a window Maintain power ventilation around the unit Avoid opening doors and windows as much as possible Avoid excess number of people in the room ...

Page 14: ...00W Operating cycle 4 9A 9000 B T U H Cooling capacity 2 9kW Dehumidifying capacity 1 6 L hour Coolant R 407C Timer 12 hour Air flow volume 490 m hour Dimensions W X H X D 47 5cm X 87 5 X 35 4cm Weight 33kgs NOTE This product should not be disposed of with household waste Please recycle where facilities exist Check with your local authority for recycling advice GET Plc Key Point 3 17 High Street P...