GET GPACU9W User Instructions Download Page 10

Note:-  In Cool and Fan mode, the fan speed can be set to High, Medium and Low.  When 
Dehumidifier mode is selected and the room temperature is below 25°C the fan speed is 
automatically set to Low and cannot be altered from this setting.  When the room temperature 
is above 26°C the fan speed is adjustable 

 
Cool Mode 

In this mode the air is cooled and hot air is exhausted through the vent hose to outside the 
room.  Fan speed and temperature can be adjusted to suit the comfort level required. 

 

Dehumidifier Mode 

Air is dehumidified as it passes through the air conditioner and the damp warm air should be 
exhausted by means of the vent hose to outside of the room. 

 

Fan Mode 

Air is cooled and circulated throughout the room.  Note:-  It is not necessary for the vent hose 
to exhaust outside the room.    
 

Fan Speed 

The fan speed can be set to high, medium or low.  Note:-  In dehumidifier mode, depending 
on the room temperature, only low fan speed is available.  (See Note in Mode Control above). 
 

Timer  

Press the Timer button to set the timer. The green LED next to the ON/OFF legend will flash 
on and off for 15 seconds. 
While the green LED is flashing, press the timer/temp adjust buttons (

▲▼

) to select the time 

(in hours, between 00 and 12)) for either of the timer modes “a” or “b” as detailed below.  The 
time selected is shown on the display panel.  After the 15 seconds the display will revert to 
showing the room temperature.     
If no time has been selected the timer will be off and the green LED will not be illuminated. 
    

Timer mode a)  Auto Turn Off

:-  With the machine on and running press Timer and then the 

Timer/Temp Adjust buttons (

▲▼

) to select the number of hours you would like the unit to run  

until it automatically shuts off.  The green timer LED will remain lit. 
 

Timer mode b)  Auto Turn On

:-   Switch the machine on using the Power button so that the 

machine is running and the desired mode is selected.  Press the Power button again to put 
the machine into stand-by mode.  With the machine in stand-by mode, press the Timer button 
and then press the Timer/Temp Adjust buttons (

▲▼

) to select the number of hours until it is 

required for the machine to start up automatically.  The green timer LED will continue to flash 
and the display will show the time set. 

 

Timer/Temperature Adjust buttons 

In Cooling or Dehumidifying mode, the temperature can be manually set by pressing the 
Timer/Temp Adjust buttons (

▲▼

) between the limits of 16° to 32°C as shown in the display 

panel.  This cannot be done in Fan mode.  The default setting is room temperature.   After 15 
seconds the display will revert back to room temperature. 

 

IMPORTANT 

When the appliance is in Cool or Dehumidifier mode, most moisture will be vented out 
through the vent pipe.  However, in certain circumstances some condensation may collect in 
the water tank at the bottom of the chassis.  When this tank is full, the “water full” indicator 

(

) will illuminate (red) and the appliance will stop running. The appliance should then be 

unplugged from the supply socket and the rubber plug in drain port at the lower rear

 

of the 

machine should be pulled out to drain the water into a suitable container. Alternatively, move 
the appliance to a suitable place to drain the water. 

Note: When the water full light (

) is on, the water should be 

drained out.   If the water is not drained out, the appliance will 
not operate. 

Summary of Contents for GPACU9W

Page 1: ...USER INSTRUCTIONS FOR GET PORTABLE 9k BTU AIR CONDITIONER MODEL No GPACU9W ...

Page 2: ...CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Troubleshooting Maintenance Energy Saving Tips Specification ...

Page 3: ...s a multi functional room air exchanging air processing appliance designed to offer you the functions of Air Conditioning Dehumidifying Independent Fan This manual will provide you with valuable information necessary for the proper care and maintenance for your new appliance Read these instructions fully before operating the unit and retain them for future reference If properly maintained your app...

Page 4: ...ring replacement ensure that equivalent rated and approved components are used See plug replacement details below 9 IMPORTANT If this unit is sited in a room containing a fuel burning appliance the installer must ensure that the air replacement is sufficient for both the unit used as an air conditioner and the fuel burning appliance PLUG REPLACEMENT If the plug is damaged and requires replacement ...

Page 5: ...Warning In order to ensure the long reliable and safe functioning of the air conditioner the following safety points should be observed ...

Page 6: ...Identification of Parts Front View Rear View ...

Page 7: ...e vent hose to reach outside the room The air intake should be a minimum distance of 50cm from any object Do not install the unit underneath desks or inside cupboards as this will restrict the operating air flow Ensure that there are no obstructions to the air intake or air outlet Ensure that the air intake is not being blocked by curtains or similar objects The end of the vent hose should not be ...

Page 8: ...available from the Helpline which also contains an external grille and a hose to pass through the wall 1 Make a suitable size hole through the external wall to accept the hose in the wall venting kit 2 Secure the flexible ducting in the wall venting kit to the wall fitting using cable ties 3 Pass the flexible ducting through the hole in the wall from the inside 4 Fix the wall fitting to the surfac...

Page 9: ...the machine is full and the machine will stop If after draining the tank the warning light remains on this could indicate that there may be a fault with the machine If this is the case do not attempt to operate the machine and call the service number Mode Control Model GPACU9W The mode control has three settings Cool Dehumidifier Fan Repeated pressing of the mode button will select the modes in or...

Page 10: ...press Timer and then the Timer Temp Adjust buttons to select the number of hours you would like the unit to run until it automatically shuts off The green timer LED will remain lit Timer mode b Auto Turn On Switch the machine on using the Power button so that the machine is running and the desired mode is selected Press the Power button again to put the machine into stand by mode With the machine ...

Page 11: ... Drain the water tank Air conditioner runs intermittently Malfunction Surrounding temperature is too high or too low Heat exhaust hose is blocked Contact the service centre Check the hose Air conditioner functions but the room is not cooled Window or door is left open in the room There is heat source in the room or too many people in it Filter is too dirty Temperature settings are too high Close a...

Page 12: ...ergent to remove stubborn stains End of season maintenance 1 Remove the water draining plug located at the rear bottom of the air conditioner replace the plug after the condensation has been drained from the water tank 2 Turn on the fan operation for a period of time to dry interior of the air conditioner 3 Remove the power cord plug from the socket and store the lead on the hooks at the back of t...

Page 13: ...ake sure you check and clean the filter each week If the filter is not kept clean it can increase your power consumption and reduce the cooling efficiency Take note of the following points Avoid direct sun light on the unit through a window Maintain power ventilation around the unit Avoid opening doors and windows as much as possible Avoid excess number of people in the room ...

Page 14: ...00W Operating cycle 4 9A 9000 B T U H Cooling capacity 2 9kW Dehumidifying capacity 1 6 L hour Coolant R 407C Timer 12 hour Air flow volume 490 m hour Dimensions W X H X D 47 5cm X 87 5 X 35 4cm Weight 33kgs NOTE This product should not be disposed of with household waste Please recycle where facilities exist Check with your local authority for recycling advice GET Plc Key Point 3 17 High Street P...