IMPORTANT SAFETY INSTRUCTIONS 

 

This heater should be installed by a competent person (i.e. a qualified electrician) in accordance with 
the current edition of the IEE wiring regulations (BS 7671) and appropriate statutory regulations. 
 
IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN 
 

 

This heater has a 2kW maximum rating and is designed for permanent high level wall mounting at a 
minimum height of 1800mm above the room floor. 
 
Before installing the heater check that the supply voltage of the installation matches the voltage 
marked on the heater. This heater is suitable for use at 230 – 240V 50Hz supply voltages. 
 

Safety Warnings 

 

• 

Do not use or install heater outdoors 

• 

Do not install the heater directly above or below a fixed socket outlet 

• 

Do not cover or obstruct heater grilles as this may cause overheating or fire 

• 

Do not use the heater to dry clothes 

• 

Do not touch the heater with wet hands 

• 

Do not use the heater if it has been dropped or damaged in any way 

• 

Do not allow any objects to be inserted in to the heater inlet or outlet grilles 

• 

Do not allow young children, the aged or infirm to use the heater without supervision  

• 

If the heater supply cord becomes damaged it must be replaced by a qualified person or 
service engineer 

• 

In the event of a fault occurring do not attempt to repair the heater. This must only be carried 
out by a qualified person or service engineer 

• 

There are no user serviceable parts supplied with the heater 

 

INSTALLATION 

 

Electrical Connection 

 

BEFORE COMMENCING ANY INSTALLATION WORK OR MAINTENANCE ALWAYS ENSURE 
THAT THE ELECTRICAL SUPPLY IS SWITCHED OFF  
 
For additional safety, remove the fuse or switch off the circuit breaker for the relevant supply circuit at 
the main fuse box or consumer unit. 
 
Ensure that no one else has access that would enable the supply to be inadvertently reconnected. 
 
The supply circuit used for connection of the heater must be appropriate for the rating of the heater 
and must be protected with a 13A fuse 
 
DO NOT CONNECT THE HEATER TO A LIGHTING SUPPLY CIRCUIT 

 

Wiring 

 

The power supply cord fitted to the heater is coloured as follows: 
 
BROWN: LIVE 
BLUE:  

NEUTRAL 

 
THIS HEATER IS DOUBLE INSULATED AND DOES NOT REQUIRE AN EARTH CONNECTION 
 
 
 
 

Summary of Contents for GM2BFHT2

Page 1: ...G2BFHT2 GM2BFHT2 INSTRUCTIONS FOR INSTALLATION AND USE 2kW WALL MOUNTED FAN HEATER Please read these instructions carefully before use and keep safe for future reference ...

Page 2: ...HEATER PARTS DESCRIPTION 1 FAN HEATER 2 OUTLET GRILLE 3 INLET GRILLE 4 WALL MOUNTING BRACKET separate 5 TOP WALL MOUNTING BRACKET hinged 6 POWER SETTING INDICATORS 7 PULL CORD 8 WALL PLUGS 9 SCREW FIXINGS 10 POWER CORD ...

Page 3: ...inserted in to the heater inlet or outlet grilles Do not allow young children the aged or infirm to use the heater without supervision If the heater supply cord becomes damaged it must be replaced by a qualified person or service engineer In the event of a fault occurring do not attempt to repair the heater This must only be carried out by a qualified person or service engineer There are no user s...

Page 4: ...ance around the heater from any flammable objects e g curtains as shown in Fig 1 2 Check to ensure that there are no hidden pipes or cables behind the wall where the heater is to be mounted 3 Place the wall mounting bracket horizontally on the wall and mark the position of the two holes 4 Using a suitably sized masonry drill for the wall plugs supplied drill the two holes to the required depth 5 S...

Page 5: ...ter power supply cord is retained by the means of termination used 14 Ensure that the correct rated fuse is fitted in the fused connection unit This should be a 13A BS1362 approved fuse 15 Switch on the circuit breaker or replace the fuse to restore power to the heater FIG 1 ...

Page 6: ... setting 1200W 5 Pull the pull cord three times to operate the fan heater at the highest heat setting 2000W both power indicators are illuminated 6 Pull the pull cord again to turn off the fan heater 7 The fan heater design incorporates an automatic safety cut out which will operate should the fan overheat due to the fan grilles becoming blocked or covered over 8 The heater and fan motor will stop...

Page 7: ...ill be free from defects in workmanship and materials for a period of 1 year from the date of purchase Any product found to have defects in workmanship or material within the period of this guarantee will be replaced free of charge The conditions of this guarantee are as follows The product has been properly maintained Defects or damage due to normal wear and tear accident misuse or interference a...