10
11
Setting and Confirmation
Volume Setting
When you turn on Power Switch(1)
while pushing Start/Stop Button(12),
[SP] is displayed and Load
Indicator(13) will light according to
present setting. The volume can be
set as LED of the Load Indicator(13)
repeats 3
➝
2
➝
1
➝
all turning off
whenever Start/Stop Button(12) is
pushed. After setting it, it becomes
usual operation by turning on Power
Switch(1) again.
Hand Button Setting
When the operation with Hand
Button(B) is unnecessary, Hand
Button(B) can be invalidated.
When you turn on Power Switch(1)
while pushing Station B Selection
Button(6), [HS] is displayed and Load Indicator(13) will light according to a
present setting. Effective and No Effect in Hand Button(B) are switched as
LED of Load Indicator(13) is lit and turned off. After setting it, it becomes usual
operation by turning on Power Switch(1) again.
How To Change Fuses
There are fuses in Inlet with Fuseholder(20). Fuses
can be changed by removing a lock on both sides,
and pulling out the fuse holder. Please use correct
fuse according to the plug.
Handpiece Holder Adjustment
Handpiece Holder(10) is attachable
with angle 60°or 90°.
Type
PH3 Controller
Rated Input
AC 120V 60Hz, 30W
AC 220V - AC240V 50Hz, 30W
Dimensions
W 200 x D 180 x H 100mm
Weight
2.3kg
Specifications
When ordering spare parts, always specify part# (or item# if applicable) and
description.
Standard Accessories
Handpiece Holder 2 piece
Power Cord 1 Piece
(100V AC17-002)
(120V AC17-100)
(230V AC17-200)
Fuse 2pcs.
(100V • 120V • UF-2A-1)
(230V UF-0.8A-1)