Gerus HP26 Operating Manual Download Page 8

  

 

 GERUS 

 

Seite 8 von 8

 

 

5  Technical data 

 

Air pressure (pB):  

 

 

 

 

1,5 

– 7,0 bar (pBmax = 15,0 bar) 

 
Output pressure (pA):  

2500 bar (max. pressure for permanent   
operating)

 

Test pressure (pprüf):  

 

 

 

2500 bar (test operating) 

 
Gadget connections: 
 

Output pressure: 

 

CEJN high pressure coupling 
(type series 125) 

Air pressure:   

 

 

 

compr. air conn. 

 9mm 

 
Masses: 
 

empty:  

 

 

 

 

30,00 kg 

filled:    

 

 

 

 

40,00 kg 

 

Dimensions: 
 

height:  

 

 

 

 

550 mm 

length:  

 

 

 

 

431 mm 

width:   

 

 

 

 

315 mm 

 
Volume of tank:  

 

 

 

 

10 l (dm³) 

 
Performance and consumption of air: 
 

0,6 m³/min for 6 bar compr. air 

≡ 1,5 dm³/min for 1000 bar 

6  After-Sales service and self-help 

 

If the  pressure  at  oil  pressure gauge 

doesn’t remain constant and drops (as described under 

point 12., the pump is not air-tight or the decompression valve 

is not fully closed. 

In most cases, this is due to the fact that the O-rings are old/worn-out. It is possible to exchange 
the O-rings. A complete set of O-rings (article-no. 11.49015-0067) is enclosed in the pump. 
The packet of spare parts can be taken out by opening the front plate 

M

. An explosion drawing of 

the pump is also included. 
 
It is recommendable to have the pump overhauled by its manufacturer 
 

GERUS APPARATEBAU GmbH & Co. KG,  
Engelschalkstraße 16  
D-86316 Friedberg 

Tel.: 0049 

– (0)821 - 588 662-0

  

FAX: 0049 

– (0)821 - 588 662-10 

E-Mail: [email protected]

 

Summary of Contents for HP26

Page 1: ...ruckpumpe HP26 Operating manual for Gerupress high pressure pump HP26 11 49015 0105 Version 2 0 Datum 19 07 2016 GERUS Apparatebau GmbH Co KG Engelschalkstrasse 16 D 86316 Friedberg e mail info gerus...

Page 2: ...anager EC Declaration of Conformity We the company GERUS Apparatebau GmbH CO KG Engelschalkstrasse 16 86316 Friedberg Germany declare hereby that the following described machine in its conception cons...

Page 3: ...von der Verordnung nur are only concerned by the regulation as als nachgeschalteter Anwender betroffen downstream user and therefore we are sind und daher nicht zur Registrierung not bound to registe...

Page 4: ...tions 5 2 Instructions for use 6 2 1 How to test a high pressure pump to see if it works 6 2 2 How to work with the high pressure pump 6 3 Risk analysis 7 4 How to exchange the oil at the high pressur...

Page 5: ...d by a security valve adjustable in the low pressure circle cf risk analysis For operating the compressed air pressure 15 bar have to be connected to the GERUPRESS the gauges have to be checked and th...

Page 6: ...ressure control valve C to the right as far as it will go until you feel a resistance 8 Check the air pressure on the pressure gauge I There should be an air pressure of at least 6 bar 9 Put start lev...

Page 7: ...evel in 1 cover cannot be closed wounding g Sufficient lubrication of the oil pump and providing with hydraulic oil is ensured by mounting the pump into the oil tank In case of a pump leakage the gadg...

Page 8: ...ce and self help If the pressure at oil pressure gauge F doesn t remain constant and drops as described under point 12 the pump is not air tight or the decompression valve B is not fully closed In mos...