![Gerus HP26 Operating Manual Download Page 8](http://html1.mh-extra.com/html/gerus/hp26/hp26_operating-manual_2217292008.webp)
GERUS
Seite 8 von 8
5 Technical data
Air pressure (pB):
1,5
– 7,0 bar (pBmax = 15,0 bar)
Output pressure (pA):
2500 bar (max. pressure for permanent
operating)
Test pressure (pprüf):
2500 bar (test operating)
Gadget connections:
Output pressure:
CEJN high pressure coupling
(type series 125)
Air pressure:
compr. air conn.
9mm
Masses:
empty:
30,00 kg
filled:
40,00 kg
Dimensions:
height:
550 mm
length:
431 mm
width:
315 mm
Volume of tank:
10 l (dm³)
Performance and consumption of air:
0,6 m³/min for 6 bar compr. air
≡ 1,5 dm³/min for 1000 bar
6 After-Sales service and self-help
If the pressure at oil pressure gauge
F
doesn’t remain constant and drops (as described under
point 12., the pump is not air-tight or the decompression valve
B
is not fully closed.
In most cases, this is due to the fact that the O-rings are old/worn-out. It is possible to exchange
the O-rings. A complete set of O-rings (article-no. 11.49015-0067) is enclosed in the pump.
The packet of spare parts can be taken out by opening the front plate
M
. An explosion drawing of
the pump is also included.
It is recommendable to have the pump overhauled by its manufacturer
GERUS APPARATEBAU GmbH & Co. KG,
Engelschalkstraße 16
D-86316 Friedberg
Tel.: 0049
– (0)821 - 588 662-0
FAX: 0049
– (0)821 - 588 662-10
E-Mail: [email protected]