Gerus HP26 Operating Manual Download Page 7

  

 

 GERUS 

 

Seite 7 von 8

 

 

3  Risk analysis 

 

a)  The oil pump is working as pressure translator, thus improper output pressures cannot be 

reached because the lower operating pressure is limited. 

b)  Improper absolute output pressures will be lock out by a additional pressure reducing valve 

in the low pressure circle. 

c)  Leaks or duct cracks in the high pressure circle including no health risks for operators. 
d)  Duct crack cause a breakdown of the output pressure. 
e)  Is  the  determined  output  pressure  not  available  after  a  short  time,  a  damage  of  the 

GERUPRESS is probably occurred. In this case, put the gadget out of operation, disconnect 
the connect air tubes. Otherwise the gadget will get dirty by hydraulic oil. 

f)  Pay attention while closing of the cover. Prohibit 

•  damaging (operating level in „1“, cover cannot be closed) 
•  wounding 

g)  Sufficient lubrication of the oil pump and providing with hydraulic oil is ensured by mounting 

the  pump  into  the  oil  tank.  In  case  of  a  pump  leakage,  the  gadget  and  the  operator  is 
protected by the casing of the tank. 
 

BE CAREFULL: Disconnect high pressure tubes only while ventilation valve open. 

 
 

4  How to exchange the oil at the high pressure pump 

 

Oil can be removed by opening the oil screw 

and by lifting the pump on the opposite side of the 

pump. 

 

BE CAREFULL: the oil starts running out as soon as you have loosened the screw! 

 

Use oil admission socket 

to fill in the oil. 

Oil level gauge 

indicates how much oil you have filled in. The pump should be

 

filled up to three 

quarters (¾).

 

 

BE CAREFULL: Only use oils with the following specifications: 

 

oil quality: anti-corrosion oil, 

viscosity approx. 13 mm² / s = cSt / 20° C

 

 
 
 

We  advise  you  to  exchange  the  oil  every  three  years  because  otherwise  the  pump  might  be 
damaged due to residues of dirt. 

 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for HP26

Page 1: ...ruckpumpe HP26 Operating manual for Gerupress high pressure pump HP26 11 49015 0105 Version 2 0 Datum 19 07 2016 GERUS Apparatebau GmbH Co KG Engelschalkstrasse 16 D 86316 Friedberg e mail info gerus...

Page 2: ...anager EC Declaration of Conformity We the company GERUS Apparatebau GmbH CO KG Engelschalkstrasse 16 86316 Friedberg Germany declare hereby that the following described machine in its conception cons...

Page 3: ...von der Verordnung nur are only concerned by the regulation as als nachgeschalteter Anwender betroffen downstream user and therefore we are sind und daher nicht zur Registrierung not bound to registe...

Page 4: ...tions 5 2 Instructions for use 6 2 1 How to test a high pressure pump to see if it works 6 2 2 How to work with the high pressure pump 6 3 Risk analysis 7 4 How to exchange the oil at the high pressur...

Page 5: ...d by a security valve adjustable in the low pressure circle cf risk analysis For operating the compressed air pressure 15 bar have to be connected to the GERUPRESS the gauges have to be checked and th...

Page 6: ...ressure control valve C to the right as far as it will go until you feel a resistance 8 Check the air pressure on the pressure gauge I There should be an air pressure of at least 6 bar 9 Put start lev...

Page 7: ...evel in 1 cover cannot be closed wounding g Sufficient lubrication of the oil pump and providing with hydraulic oil is ensured by mounting the pump into the oil tank In case of a pump leakage the gadg...

Page 8: ...ce and self help If the pressure at oil pressure gauge F doesn t remain constant and drops as described under point 12 the pump is not air tight or the decompression valve B is not fully closed In mos...

Reviews: