background image

8

  8.0  Trouble shooting  

 

To avoid unnecessary disappointments, you should check the following before contacting the Gerni service 
organization:

Symptom Cause 

Recommended 

action

Machine refuses to start

 

Machine not plugged in 

Plug in machine.

 

Defective socket 

Try another socket.

 

Fuse has blown 

Replace fuse. Switch off other machines.

 

Defective extension cable 

Try without the ex ten sion cable.

Machine stops

 

Fuse has blown  

Replace fuse. Switch off other machines. 

 

Incorrect mains voltage 

Check that the mains voltage corresponds to  

 

 

specifi cation on the model tag.

 

Thermal sensor activated 

Wait - the machine will start after a few   

 minutes
 

 

WARNING! 

The trigger of the spray gun  

 

 

must not be activated.

Fuse blows

 

Fuse too small 

Change to an installation higher than the  

 

 

amp. consumption of the machine. 

 

 

You may try without the extension cable.

Machine pulsating

 

Air in inlet hose/pump 

Allow machine to run with open trigger until  

 

 

regular working pressure resumes.

 

Inadequate supply of  

Check that the water supply corresponds to  

 

mains water 

specifi cations required (see model tag) 

 

 

NB!

 Avoid using long, thin hoses (min 1/2")

 

Nozzle partially blocked 

Clean the nozzle (see section 4.1)

 

Water fi lter blocked 

Clean the fi lter (see section 4.2)

 

Inlet hose kinked 

Straighten out hose.

 

Machine often starts 

Pump/spray gun is 

Contact your nearest Gerni Service Centre.

and stops by itself 

leaking

Machine starts, but 

 

Pump/hoses or accessory 

Wait for pump/hoses or accessory to thaw.

no water comes out 

 frozen

 

No water supply  

Connect inlet water.

 

Water fi lter blocked 

Clean the fi lter (see section 4.2)

 

Nozzle blocked 

Clean the nozzle (see section 4.1)

Pump pressure drops

 

Button for regulation of  

Adjust the button to correct working pressure.

 

pressure / water volume not 

 correctly 

adjusted

In case problems other than the above occur, please contact your local Gerni distributor.

Summary of Contents for Ultimate 130.1

Page 1: ...128303530 Ultimate 130 1 User Guide Ultimate 130 1 Why compromise...

Page 2: ...Printed in China Copyright 2010 Gerni...

Page 3: ...zzle 8 Needle for cleaning of nozzle 9 Detachable container for detergents 10 Dosing regulator for detergents 11 Pressure gauge 12 Regulation of pressure water volume 13 Hose reel Specifications See m...

Page 4: ...ot allowed to clean asbestos containing surfaces with high pressure Safety devices Locking device on spray gun The spray gun features a locking device 4b When the pawl is activated the spray gun canno...

Page 5: ...tension hose is applied 1 Fill the container with a detergent 2 Mount the TORNADO PR nozzle and adjust it to low pressure see section 2 4 4 3 Adjust the dosing regulator 11 to the required volume of d...

Page 6: ...ation 1 Stop the machine by turning the start stop switch 2 to pos O 2 Disconnect the plug from the socket 3 Shut off the water supply and activate the trigger 5a to relieve the machine of pressure Co...

Page 7: ...zen it will be necessary to check it for damage NEVER START UP A FROZEN MACHINE Frost damages are not covered by the guarantee WARNING Always disconnect the plug from the socket prior to maintenance o...

Page 8: ...ion cable Machine pulsating Air in inlet hose pump Allow machine to run with open trigger until regular working pressure resumes Inadequate supply of Check that the water supply corresponds to mains w...

Page 9: ...that only original accessories have been applied that the product has not been exposed to abuse such as knocks bumps or frost that only water without any impurities has been used that the high pressu...

Page 10: ......

Page 11: ......

Page 12: ...fisk Advance Pty LTd 48 Egerton St Silverwater NSW 2128 Phone 1300 556 710 E mail sales gerni com au NEW ZEALAND Accent Tools Ltd 232 Bush Rd Albany Auckland 0632 Phone 09 968 2610 E mail sales accent...

Reviews: