background image

*) 

Optional accessories / Option depending on model

Original instruction

10

Quick reference guide

This high pressure washer has been designed for 
professional use typically in following cleaning ap-
plications:
floor/wall, auto/truck, buildings/constructions, con-
tainer/barrel and craftsman use.

The pictorial quick reference guide

The pictorial quick reference guide is designed for 
helping you when starting up, operating and storing 
the unit. The guide are subdivided into 5 sections.

A

 

Before starting

DO READ SAFETY INSTRUCTIONS BEFORE USE!

Operating elements:

1.  Inlet water connection
2.  Nipple for high pressure hose
3. Lifting 

handle

4. Cabinet
5. Cable 

release

6. Oil 

sight

7. On/off 

switch

8. Lance
9.  Holder for lance
10.  Ergo 2000 spray handle
11. Child lock
12.  Holder for spray lance*)
13.  Holder with a 2½ l canister *)
14. Cabinet lock
15.  Foam Sprayer *)
16.  Flexo Power lance*)
17.  Placement for lances 
18.  Cable end fixation 
19. Foot kick
20.  Holder for Foam Sprayer/Canister lid*)
21.  Hose hook *)   

Assembling the unit:

1.1 

Mount filter and Gardena coupling

1.2 

Mount the seal and 3/8” nipple on high 
pressure outlet

1.3 

Connect hoses  (water and high pressure 
hose)

1.4 

Mount the lance

1.5 

Connect the electrical cable to mains. 

B

Switching on the unit

1.0 

Check oil level  (see E1.2)

1.1 

Open water tap

1.2 

Switch on the High Pressure Washer

1.3 

Open child lock at spray handle

1.4 Activate 

sprayhandle

C

Control/operation

Using cleaning agents:

1.0 

Check / clean hole in suction limiter at Foam

 Sprayer

1.1 

Mount Foam Sprayer at canister 

1.2 

Set spray angle horizontal/vertical

1.3 

Activate spray handle.

Adjust pressure at FlexoPower lance (Standard 
models):

3.0 

Turn the blue part of the nozzle head Min./  
max.

Cable unwind and storage:

4.0 

Turn the cable hook for cable release /  

 

storage

4.1 

Fixate cable end at Hose hook after use

D

After using the unit

1.0 

Switch off the High Pressure Washer

1.1 

Disconnect from mains 

1.2 

Turn off the water 

1.3 

Release pressure at spray handle

1.4 

Set child lock 

1.6 

Place spray handle and lance in holders 

E

Maintenance

1.0 

Unlock cabinet opening cabin locks (use    
coin or screwdriver)  

1.1 Remove 

cabinet

1.2 

Check / tip up oil to max (SAE 80W-90)

1.3 

Oil max v.s. pumptype MC 4M (NA4)

Summary of Contents for MC 4M

Page 1: ...107145556 C 03 2015 MC 4M Operating instructions...

Page 2: ...fe and in proper condition and in upright posi tion on a plain and stable ground to ensure stability Regularly check whether the power cord is damaged or shows signs of ageing WARNING Do not use the m...

Page 3: ...r mains when an ap propriate backflow preventer has been installed Type BA according to EN 60335 2 79 The backflow preventer can be ordered under number 106411177 106411178 106411179 106411184 The len...

Page 4: ...nded Always remove the plug from the mains plug socket before carrying out mainte nance work or cleaning of the machine Carry out only the maintenance operations described in the operating instruction...

Page 5: ...5 A 6 5 13 18 19 21 20 15 1 3 4 7 8 9 10 11 14 17 2 16 12...

Page 6: ...6 1 4 1 5 1 3 1 1 1 2 B O I 1 0 1 1 1 2 1 3 1 4 BA Valve BA Valve...

Page 7: ...7 1 1 1 2 1 3 1 0 MAX CHEM 3 0 MIN MIN C 4 0 4 1...

Page 8: ...8 1 0 1 2 O I 1 1 1 3 1 4 8 1 1 6 MAX MAX 5 1 MC 4M D...

Page 9: ...9 E 10 2 1 2 1 3 1 1 1 0...

Page 10: ...unit 1 1 Mount filter and Gardena coupling 1 2 Mount the seal and 3 8 nipple on high pressure outlet 1 3 Connect hoses water and high pressure hose 1 4 Mount the lance 1 5 Connect the electrical cable...

Page 11: ...for replacement of power cable Plug is not inserted in mains Insert plug Mains fuse is blown Reset power mains Plug has a loose connection to cable Repair reassemble plug on cable skilled electrician...

Page 12: ...5 1 2012 EN 60335 2 79 2012 EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 1997 A1 2001 A2 2008 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 11 2000 EN 50581 2012 Following the provisions of Machinery Dir...

Page 13: ...ure bar MPa 200 20 8 QMAX Water flow l h 620 9 tmax Max water inlet temperature Intake Pressure operation C F 60 40 max 1 h 140 104 max 1 h 10 pmax Max water inlet pressure bar MPa 10 1 11 Max dry suc...

Page 14: ......

Page 15: ......

Page 16: ...AUSTRALIA Nilfisk Advance Pty LTd Unit 1 13 Bessemer Street Blacktown NSW 2148 Phone 1300 556 710 E mail sales gerni com au...

Reviews: