13
CONNECTION DIAGRAM
CAUTION! VOLTAGE OF HEATING
ELEMENTS 220V~240V.
For 220V-240V Earth one phase
connect on: (brown wire) connect
to L and (blue wire) connect to N,
Safety wire (yellow green) connect to
Connect the wires as indicated
in the image to the right, using
the brass links provided
where necessary.
The earthing (yellow/green)
conductor must always be 10mm
longer than the line conductors.
Please take care to ensure that the temperature of the mains supply cable does
not exceed 50°C.
Regularly check the power cord for damage. If the supply cord is damage, it must
be replaced by the manufacturer, its service agent or similarly qualified persons in
order to avoid danger or injury.