CRH 9

2. Table of contents

1  Overview ....................................................................................................................................................................... 2

2  Table of contents ...........................................................................................................................................................3

3  Technical specifications .................................................................................................................................................3

4  Operating instructions ...............................................................................................................................................4–6

5  Customer service  .......................................................................................................................................................... 7

6  Installation ..............................................................................................................................................................8–13

Warranty Terms and Conditions  ......................................................................................................................................38

Customer Service Center  .................................................................................................................................................39

3. Technical specifications

Type

CRH 9

Capacity

0.2 litre

Pressure-type, rating pressure

6 bar

Heating system

Tubular heater

Nominal rating

8.0 kW ~ 9.6 kW

Rated voltage (50 / 60 Hz)

220 – 240 V

Rated current at 220 V 

36.4 A

Min. required conductor cross-section

3 × 6.0 mm

2

Factory preset flow reducer

5.0 l/min

Increase of temperature ∆t at present flow

23 K

Hot water temperature at 20 °C inlet temp.

 43 °C 

Switch-on flow rate

2 l/min

Useful for cold water up to

30 °C

Water connection

½“ B.S.P. surface-mounted or flush-mounted

Net weight and dimensions (H × W × D)

2.2 kg / 33 × 21 × 9 cm

Protection class and type of protection to VDE

1 / IP25

Safety mark

see type plate

3

Operating Instructions:  
Please read these instructions carefully before using the appliance!

中文使用說明書從第 14 頁開始   –   

Traditional Chinese manual starts on page 14. 

中文使用說明書從第 25頁開始

   –   

Simplified Chinese manual starts on page 25. 

Summary of Contents for CRH9

Page 1: ...Instantaneous Water Heater CRH9 WH CRH M 10 2 Printed in Germany Please read these instructions and warranty information carefully before use and keep them handy for future reference WH CRH M 11 3...

Page 2: ...ng and serial number Pos Description 1 Brass connection set with back flow prevention in hot water outlet 2 Temperature monitor 3 Heating element 4 Safety thermal cut out Pos Description 5 Differentia...

Page 3: ...20V 36 4A Min required conductor cross section 3 6 0mm2 Factory preset flow reducer 5 0 l min Increase of temperature t at present flow 23K Hot water temperature at 20 C inlet temp 43 C Switch on flow...

Page 4: ...iance must be vented correctly in accordance with the instructions in this manual Do not remove the front cover under any circumstances before switching off the mains electrical supply to the unit Nev...

Page 5: ...ared between the outlets Therefore you should use only one outlet at the time to have a sufficient flow and to avoid variation in temperature Temperature monitor If the temperature rises too high the...

Page 6: ...tion piece positionI 6 Vent the unit by carefully opening and closing the af filiated warm water tap valve several times until air no longer emerges from the pipe Cleaning the fine filter surface mou...

Page 7: ...eset The pilot lamp Power lights water remains cold Heating element or electronics faulty Reset fuse water remains cold contact customer service Safety thermal cut out tripped Reset In case of repeate...

Page 8: ...connections of the wall Mark the drill holes and drill them using a 6 mm drill 5 Mount the unit to the wall and connect the water supply of the unit together with the 3 8 seals 6 Open the water suppl...

Page 9: ...t then be screwed into the 3 8 union nut of the appliance and delivery pipe together with the 3 8 seals 6 Mark the drill holes and drill them using a 6 mm drill Mount the unit to the wall and connect...

Page 10: ...e complies with protection type IP25 and may be installed in zone 1 acc IEC In order to avoid thermal losses the distance between the heater and the tapping point should be as small as possible 2 m Be...

Page 11: ...insert the connecting lead The lead must be secured with the cable clamp when using a flexible power cord 5 Screw the appliance into position using the enclosed raw plugs and screws 6 Install the appl...

Page 12: ...shutoff valve 8a in the cold water connection position I if necessary Check all connections for leaks 10 Next open and close the hot water tap several times until no more air emerges from the line and...

Page 13: ...slightly smaller than the cross section of the cable in order to ensure optimum protection against water Fit the grommet into the opening The protection grommet must be used The appliance must be eart...

Page 14: ...14 CRH9 1 6 7 2 3 4 5 1 1 2 3 4 STB 5 6 7...

Page 15: ...15 CRH9 2 1 14 2 15 3 15 4 16 18 5 19 6 20 25 38 39 3 CRH9 0 2 6bar 8 0 kW 9 6 kW 50 60Hz 220 240 V 220 V 36 4A 3 6 0mm2 5 0 l min t 23K 20 43 2 l min 30 1 2 B S P H W D 2 2kg 33 21 9cm VDE 1 IP25...

Page 16: ...16 CRH9 4 43 30...

Page 17: ...17 CRH9 3 N PE 380 400 V Power 40 60 Overheat 1 2 1 3 4...

Page 18: ...18 CRH9 4 II I 8a 8c 8b 8 1 II 8a 2 8b 8c 3 4 5 I 6 8 1 2 8d 3 4 5 6 8d...

Page 19: ...19 CRH9 5 German Pool LED Power Pressure...

Page 20: ...20 CRH9 6 CRH 9 2 1 2 12 mm 12 mm 3 P T F E 1 2 4 6 mm 5 3 8 6 8a I 7...

Page 21: ...21 CRH9 6 8d 1 2 1 2 1 2 1 2 3 1 2 4 8d 5 3 8 3 8 6 6 mm 7 8 8a 9...

Page 22: ...22 CRH9 6 IP25 IEC 1 2 m 3 bar 6 bar...

Page 23: ...23 CRH9 6 1 2 3 6 mm 4 5 6 7 P T F E 8...

Page 24: ...24 CRH9 6 II I 8a 9 I 8a 10...

Page 25: ...25 CRH9 6 I 1 3 mm 2 3 4 5 6 German Pool www germanpool com...

Page 26: ...26 CRH9 1 6 7 2 3 4 5 1 1 2 3 4 STB 5 6 7...

Page 27: ...27 CRH9 2 1 26 2 27 3 27 4 28 30 5 31 6 32 37 38 39 3 CRH9 0 2 6bar 8 0 kW 9 6 kW 50 60Hz 220 240 V 220V 36 4A 3 6 0mm2 5 0 l min t 23K 20 C 43 C 2 l min 30 C B S P H W D 2 2kg 33 21 9cm VDE 1 IP25...

Page 28: ...28 CRH9 4 43 C 30 C...

Page 29: ...29 CRH9 3 N PE 380 400 V Power 40 C 60 C Overheat 1 2 1 3 4...

Page 30: ...30 CRH9 4 II I 8a 8c 8b 8 1 II 8a 2 8b 8c 3 4 5 I 6 8 1 2 8d 3 4 5 6 8d...

Page 31: ...31 CRH9 5 German Pool LED Power Pressure...

Page 32: ...32 CRH9 6 1 2 12 mm 12mm 3 P T F E 1 2 4 6 mm 5 3 8 6 8a I 7 CRH9 2...

Page 33: ...33 CRH9 6 1 2 1 2 1 2 1 2 3 1 2 4 8d 5 3 8 3 8 6 6 mm 7 8 8a 9 8d...

Page 34: ...34 CRH9 6 IP25 IEC 1 2 m 3 bar 6 bar...

Page 35: ...35 CRH9 6 1 2 3 6mm 4 5 6 7 P T F E 8...

Page 36: ...36 CRH9 6 II I 8a 9 I 8a 10...

Page 37: ...37 CRH9 6 I 1 3mm 2 3 4 5 6 German Pool www germanpool com...

Page 38: ...2 Customer should always follow the operating instructions This warranty does not apply to any accessories and auxiliary devices damages caused by accidents of any kind including transport and others...

Page 39: ...ok Road Tokwawan Kowloon H K Tel 852 2333 6249 Fax 852 2356 9798 Email Address repairs germanpool com 116 2 4 852 2333 6249 852 2356 9798 repairs germanpool com China 86 400 830 3838 86 0757 2336 0284...

Page 40: ...be prosecuted 852 2333 6245 852 2773 2888 info germanpool com 116 2 4 116 2 4 852 2765 8215 852 2365 6009 Tel Fax E mail German Pool Hong Kong Limited Room 2 4 Upper Ground Floor Newport Centre 116 M...