GLP
German Light Production
(V1.11)
21
Position
Interval
In this way
Outside optic
weekly
soft cloth and glass cleaning fluid
Color filter
monthly
soft cloth and glass cleaning fluid
Gobos
yearly
vacuum cleaner, airbrush, etc.
Glass gobos
monthly
soft cloth and glass cleaning fluid
Prism
monthly
soft cloth and glass cleaning fluid
Dimmer/Shutter
yearly
vacuum cleaner, airbrush, etc.
Inside lens
monthly
soft cloth no glass cleaning fluid
Fan and air channel
monthly
vacuum cleaner, airbrush, etc.
Reflector
never
Lamp
never
Moveable parts
yearly
suitable fatty oil
Attention:
1. Never let optical parts come into contact with oil or grease.
2. Wait until all parts are dried up before operating the fixture.
6.3 Cleaning the Optical System
1. Pull out the main plug!
2. Wait at least 20 minutes after the last operation to cool down the fixture.
3. Remove the Roto Head by loosening the 6 head-screws.
4. Remove the inside optical plug-in by loosening the two hexagon socket screws
and pull it out.
5. Clean all glasses, lenses and mirrors carefully.
6. Before you put the
M
M
I
I
N
N
I
I
P
P
A
A
T
T
E
E
N
N
D
D into operation close the casing, otherwise
your retina can be hurt!